LK Automation Limited
Home >> Download >> MITSUBISHI >> Manual Download >> MITSUBISHI QJ71PB92V  Manual QJ71PB92V  User's Manual

MITSUBISHI QJ71PB92V  Manual QJ71PB92V  User's Manual

Product model: QJ71PB92V 
Name: PROFIBUS-DP Interface Module
Brand: MITSUBISHI
Sort: User's Manual
File language: English
File size: 2.35MB
Input / output points: 4096 points.
You can use the CF card.
Version OS:VxWorks 6.4.
Simply insert the SD memory card, you can automatically record.
Simply insert the SD in the CPU to save the record setting file, you can automatically start recording.
Even when remote data collection is required,
After receiving a record setting file by mail and copy it to the SD memory card,
Can immediately start recording QJ71PB92V  User's Manual QJ71PB92V 
Automatically transfer the record file to the FTP server
Simply by recording the configuration tool to carry out a simple setup,
A data record file stored on the SD memory card can be sent to the FTP server.
Because the record server can handle multiple files, it can reduce the task of management and maintenance QJ71PB92V  User's Manual.
When a failure occurs, it can quickly respond to.
Simply extract the data associated with the problem, do not have to spend a lot of time to filter a large number of diagnostic data,
So it can quickly determine the cause of the failure, and make the solution.Adapter for mounting DIN guide rail.
For Q32SB, Q33SB, Q35SB, Q33B, Q52B, Q55B, Q63B.Input and output points: 1024 points QJ71PB92V  User's Manual.
Input / output data points: 8192 points.
Program capacity: 60k.
Basic command processing speed (LD command) S:0.2.
PLC in the program execution stage: according to the order of the user program order to store the order of each instruction,
After the corresponding operation and processing, the result is written to the output status register,
The contents of the output status register are changed with the execution of the program.
Output refresh phase: when all instructions are executed,
The output status register is sent to the output latch in the output refresh stage,
And through a certain way (relay, transistor or transistor) output, drive the corresponding output equipment. Application: Q series.
Suitable for safety standards: EN954-1 class 4, PLe ISO13849-1.
Security input points: 1.
Add up to 3 additional units: safety relay module.
Use special setting monitoring tools to configure the configuration directly.
Constitute a rich set of componennts can be easily and quickly set the hardware structure QJ71PB92V  Manual.
Creating logic for security devices, by using the automatically generated labels of the FB can easily create logic.
Logical import and export.
You can store the connecttion settings of the input and output modules and the application logic created by the function block as a setting file,
Or read from a saved set file QJ71PB92V  Manual.