Battery replacement.
Initial voltage 3.0V.
Replacement of large capacity battery module without cable.
Current capacity: 18000mAh.
Service life: 5 years.
Outline dimension: 98*55.2*87mm.Input points: 32 points.
Input voltage and current: 4mA DC24V.
Response time: 1/5/10/20/70ms.
32 point /1 a public side QJ71PB93D Manual.
Common anode.
40 pin connector.
Easy connection programming tool via ethernet
QJ71PB93D
Programming tools (Works2 GX, Developer GX) and CPU direct connection (1 to 1),
No need to carry out the IP address settings. And there is no need to select the cable, the straight line and the cross line can be used.
Therefore, this connection method and the use of USB, can easily communicate with the CPU,
Even the operators are not familiar with the network settings can easily establish a connection QJ71PB93D Manual.
A variety of modules with excellent performance,
Meet the needs of various control from analog to location.
Q series module products include a variety of types of I/O, analog and positioning function module.
Can fully meet the switch, sensor, such as the input and output, temperature, weight, flow and motor, drive control,
As well as the requirements of high-precision control of the positioning of the industry, the control needs of various fields QJ71PB93D Manual.
Can also be used in combination with the CPU module to achieve appropriate control.
Continue to go beyond, to climb the peak of Q series MITSUBISHI Slave Module Manual.
Strengthen security function.
Can be set up to 32 characters of the file password.
In addition to the English letters, numbers, but also the use of special characters,
To further enhance the security of the password MITSUBISHI Slave Module Manual.
In addition, only pre registered devices are allowed to access CPU,
To intercept unauthorized access to unauthorized users.
Therefore, it is important to prevent the outflow of important program assets and protect intellectual property rights MITSUBISHI Slave Module Manual. SRAM memory card.
RAM capacity: 512KB. Relay output: 32.
Rated current and voltage: DC24V/AC240V, 2A/1 point, 5A/1 public end, 8 point 1 Public end.
External wiring connections: 38 terminals (terminals sold separately).
Replacement model: AY13.Three-phase 4 wire type.
Measuring circuit number: 1 circuits.
Measurement items: power consumption (consumption, regeneration), current, voltage, power, power factor, etc..
Power measurement module product group capable of simply measuring various energy information.
With only one module can be used to measure and power consumption (consumption and regeneration), reactive power, current, voltage, power, power factor and frequency of all kinds of detailed information.
No ladder program can continue to monitor the minimum and maximum values, can also perform 2 types of upper / lower limit alarm.
Only in the ON state can be used to measure the output of the output device.
Therefore, the amount of electricity and the quantity of electricity in the unit of the beat can be obtained during the operation of the equipment.
3 phase 3 wire products can be used too measure up to 4 circuits in one slot,
3 phase 4 wire products can be used to measure up to 3 circuits,
So the electrical energy measurement can be carried out in a small space by the multi circuit products QJ71PB93D User's Manual.
For example, a module ccan be used to measure other loads from the control panel trunk QJ71PB93D Manual.
In addition, Works2 GX (version 1.90U and higher) can be used to easily set parameters.