Output method: Transistor sinking.
Inputs: 12.
Outputs: 8.4 Axis Position Control and Comprehensive Programmable Controller.
The CP1H-X with pulse outputs for 4 axes.
The CP1H-Y with 1-MHz pulse I/O.
The CP1H-XA with pulse outputs for 4 axes and built-in analog I/O. Specifications: 4 Kwords with clock CJ1W-DA041 Instruction Installation Sheet. Name: High-speed Counter Module.
Model: C200H-CT021
CJ1W-DA041
Number of axes: 2 axis/Unit.
Operating modes: 7.
High-speed Counter Unit
A High-speed Counter Unit counts input signals from incremental rotary encoders or other sources.Output method: Relay.
Inputs: ---.
Outputs: 16.Product name: E@@S type CPU Units with 40 I/O Points.
Specifications: Power Supply, 100 to 240 VAC; Inputs, 24; Outputs, 16;
Output type: Relay CJ1W-DA041 Instruction Installation Sheet.
Program capacity: 2K steps.
memory Data capacity: 2K words.
External powersupply(24 VDC): 0.30A.
Current consumption: 5 V, 0.17A; 24 V,0.09A.
Standards: UC1, N, L, CE.
The CP1E Programmable Controller: Economical, Easy to use, and Efficient.
The E@@(S)-type Basic CPU Units provide cost,
performance and easy application with only basic functionality.
The N@@(S@) and NA-types Application CPU Units,
support Programmable Terminal connection, position control,
and inverter connection CJ1W-DA041 Instruction Installation Sheet. Product name: CS1 Expansion Backplanes.
Specifications: For CS-series,
Unit only Note: C200H series,
Units cannot be mounted; 3 slots.
Mountable configuration units:
Basic I/O Units, CS-series Basic I/O Unit,
Yes; C200H series Basic I/O Unit, No;
C200H Group-2 High density I/O Unit, No.
Special I/O Units: CS-series Special I/O Unit,
Yes; C200H series Special I/O Unit, No.
CPU Bus Units: CS-series CPU Bus Unit, Yes.
Current consumption: 5V system, 0.23A;
26 V system, --.
Standards: U, C, N, L, CE.
Multi-application Controllers:
From High-performance Machine C,
Highly Reliable Process Control. Name: Heat/Cool Temperature Control Module.
Model: C200H-TV103.
Sensor: Platinum resistance thermometer: JPt100, Pt100.
Control output: Current output(transistor output used for cooling outputs).I/O Terminal Cover For 38-pin block, standard C500-COV12Unit type: CJ1 Special I/O Units.
Product name: Analog Output Unit.
I/O points: 4 inputs ; 2 outputs.
Signal range selection:
Set separately for each input and output.
Signal range, Resolution: 1 to 5 V,
0 to 5 V, 0 to 10 V, -10 to 10 V,
4 to 20 mA.
Resolution: 1/4,000 (Settable to 1/8,000).
Conversion period: 1 ms/point,
(Settable to 500 μs/point).
Accuracy at ambient temperature of 25°C:
Voltage: ±0.2% of F.S. Current: ±0.2% of F.S;
Voltage: ±0.3% of F.S. Current: ±0.3% of F.S.
External connection: Removable terminal block.
External power supplyy: 24 VDC +10% -15%, 140mA max CJ1W-DA041 Manual.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.58A; 24V, --.
Standards: UC1, N, L, CE.
Consistent Microsecond Throughput:
Models with Direct Conversion Join the Lineup.
Anaalog Input Units for converting analog input,
signals into binary data CJ1W-DA041 Manual.
Analog Output Units for converting binary ,
data into analog output signals.