Unit type: CJ1 Basic I/O Units.
Product name: Transistor Output Units.
Specifications: Output type, Sinking;
I/O points, 32 outputs;
Maximum switching capacity, 12 to 24VDC, 0.5A;
Commons, 16 points, 1 common;
External connection, Fujitsu connector.
No. of words allocated: 2 words.
Current consumption: 5V, 0 CJ1W-DA042V . 14A; 24V, --.
Standards: UC1, N, L, CE.
A Wide Range of Basic Output,
Units for High Speed Output,
and Different Applications
CJ1W-DA042V
These Output Units receive the ,
results of output instructions ,
from the CPU Unit and perform ON/OFF,
control for external devices.
High-speed Output models CJ1W-OD213 and,
CJ1W-OD234 can help to increase system.
throughput. C200H Power Supply Aux PS for SLK11 C200H-APS03 CJ1W-DA042V .
Required when supplying backup power.C500-IA I/O Unit AC Input 32 pts C500-IA122(3G2A5-IA122).
AC100-120V 10mA.Model: C200H-OD212.
No. of points: 16 pts.
Specifications: 0.3 A, 24 VDC.C500-ID Special I/O Unit ID Sensor Unit General Purpose C500-IDS01-V2Model: C200H-DA004.
Input points: 8.Product name: N@@-type CPU Units with 20 I/O Points.
Specifications: Power Supply, 100 to 240 VAC; Inputs, 12; Outputs, 8;
Output type: Transistor (sourcing) CJ1W-DA042V .
Program capacity: 8K steps.
memory Data capacity: 8K words.
External powersupply(24 VDC): --.
Current consumption: 5 V, 0.23A; 24 V,0.02A.
Standards: UC1, N, L, CE.
The CP1E Programmable Controller: Economical, Easy to use, and Efficient.
The E@@(S)-type Basic CPU Units provide cost,
performance and easy application with only basic functionality.
The N@@(S@) and NA-types Application CPU Units,
support Programmable Terminal connection, position control,
and inverter connection. Unit type: CS1 Special I/O Units.
Product name: Isolated-type,
Thermocouple Input Units.
points Input: 4 inputs.
Signal range selection:
Set separately for each input.
I/O type: R, S, K, J, T, L, B.
Conversion speed: 250 ms/4 inputs.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.25A; 26V, --.
Standards: UC1, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in cost and space compared,,
with previous systems CJ1W-DA042V Instruction Manual.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCCUs,
to construct complete process control systems CJ1W-DA042V Instruction Manual.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.