Unit type: CJ1 Basic I/O Units.
name: B7A Interface Units.
Specifications: I/O points, 32 inputs/outputs;
External connection, Removable terminal block.
No. of words allocated: 4 words.
Current consumption: 5V, 0.07A; 24V, --.
Standards: UC1, CE.
It transmits 16 points of I/O signals per,
word with a pair of cables CJ1W-SCU42 Manual.
Easy and minimized wiring effort,
The B7A Interface Unit and B7A Link Terminal,
can be used in the same way as a standard,
Basic I/O Unit and I/O Terminal without,
any need to worry about communications
CJ1W-SCU42
This characteristic reduces the wiring,
when using more than one relatively remote,
sensor or actuator.
Name: e-CON Connectors.
Specifications: Outputs; 8 outputs ; PNP;
Without Short-circuit and,
Disconnected Line Detection CJ1W-SCU42 Manual.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site CJ1W-SCU42 Manual.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. Unit type: CS1 Special I/O Units.
Product name: Isolated-type,
2-Wire Transmitter Input Unit OMRON Communications Boards Manual.
Input points : 4 inputs.
Signal range: 4 to 20 mA, 1 to 5 V.
Conversion speed (resolution):
100ms/4 inputs OMRON Communications Boards Manual.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.15A; 26V, 0.16A.
Standards: UC1, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value OMRON Communications Boards Manual.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in cost and sppace compared,
with previous systems CJ1W-SCU42 Safety Precautions.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCCUs,
to construct complete process control systems CJ1W-SCU42 Manual.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.