A memory card suitable for Phoenix PCM+3.2 and one of thefollowing Bus Connection Units is required.
No PC card is provided with the Unit.Unit type: CS1 Basic I/O Units.
Product name: DC Input Unit.
Specifications: 24 VDC, 7 mA,
16 inputs.
Mountable Racks: CPU Rack, CS1W-BC,
@@3,YES, @@2, YES;
C200HX/HG/HE Expansion I/O Rack, No CP1W-40EDT Manual.
CS1 Expansion Rack, CS1W-BI,@@3,YES,
@@2, YES; CS1 Long distance Expansion Rack,
Yes; SYSMAC BUS Slave Rack, No
CP1W-40EDT
Words required: (I/O bits: CIO 0000 to CIO 0319), 1 word.
Current consumption: 5V system, 0.10A;
26 V system, --.
Standards: UC1, N, L, CE.
Multi-application Controllers:
From High-performance Machine C,
Highly Reliable Process Control CP1W-40EDT Manual. Model: C200H-ID212.
No. of inputs: 16 pts.
Input voltage: 24VDC, +10%/–15%.
Input current: 7mA, 24VDC.
Isolation: Photo-coupler.
Indica-tor: LED.
External connec-tions: Remove-able termi-nal blocks.
Inputs percom-mon: 16 pts.
Internal currentcon-sump-tion: 10mA max.For 5-slot Backplane.Unit type: CJ1 Basic I/O Units.
Product name: DC Input/Transistor Output Units.
Specifications: Output type, Sinking;
I/O points, 16 inputs, 16 outputs;
Input voltage,Input current,
Maximum switching capacity, 24VDC, 7mA,
12 to 24 VDC, 0 CP1W-40EDT Manual. 5 A;
Commons, 16 points, 1 common;
External connection, MIL connector.
No. of words allocated: 2 words.
Current consumption: 5V, 0 OMRON Expansion I/O Units Manual. 13A; 24V, --.
Standards: UC1, N, CE.
A Wide Range of Basic Mixed,
I/O Units for Different Applications,
and Wiring Methods OMRON Expansion I/O Units Manual.
One Mixed I/O Unit has connectors for,
both inputs and outputs.
Use Mixed I/O Units to easily ,
build space-saving systems. I/O Cable (for I/O to Interface Racks) 10 m (L) CV500-CN132Model : C500-FZ001.
C500-FZ Special I/O Unit Fuzzy Logic Unit C500-FZ001.The initial configuration of the G language unit in the industry due to the use of G language,
Complex processing procedures do not need to be able to make the ladder diagram OMRON Expansion I/O Units Manual.
The realization of the first 1 axis simultaneous control of 4 axis simultaneous control in the industry is due to the multi task function,
Can be executed at the same time or the 2 axis simultaneous control of 4 axes, and then can achieve the 4 axis independent control, etc.
Up to 8 units can be installed CVM1 8 units can be installed 1 units, can control up to 32 axes.
Applicable to ABS encoder by standard,
Applicable to the ABS type (aabsolute output) encoder, so after the emergency stop, no need to search for the origin, etc CP1W-40EDT I/O Wiring Diagram. .
S curve also according to the standard configuration plus deceleration curve, in addition to the trapezoidal outside,
Also configured too suppress the mechanical vibration of the S shape curve CP1W-40EDT Manual.
Program login maximum of up to 100
G language can be programmed with the MC support software G