Unit classification: CJ1 Special I/O Units.
Product name: Process Input Units,
(Isolated type Units with Universal Inputs).
Input points: 4 inputs.
Signal range selection:
Set separately for each input.
Signal range:Fully universal
inputs: Pt100, JPt100, Pt1000, K,
J, T, L, R, S, B, 4 to 20 mA, 0 to 20 mA,
1 to 5 V, 0 to 5 V, 0 to 10 V CS1G-CPU44-V1 INSTRUCTIONS REFERENCE MANUAL.
Conversion speed (resolution): Conversion,
speed: 250 ms/4 inputs
CS1G-CPU44-V1
Accuracy at ambient temperature of 25°C:
Accuracy: Platinum resistance thermometer,
input: ±0.3% of PV or ±0.8°C, whichever,
is larger) ±1 digit max. Thermocouple input:
(±0.3% of PV or ±1.5°C, whichever is larger),
±1 digit max. *1 Voltage or current input:
±0.3% of F CS1G-CPU44-V1 INSTRUCTIONS REFERENCE MANUAL. S. ±1 digit max.
External connection: Removable terminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.32A; 24V, --.
Standards: UC1, L, CE.
A Single Unit Handling All Types of Inputs,
such as Temperature Sensor Inputs and,
Analog Signal Inputs (e.g., 4 to 20 mA or 1 to 5V).
A Unit supports four input channels,
each of which can be set to a
platinum resistance thermometer, thermocouple,
and DC signal (current, voltage) CS1G-CPU44-V1 INSTRUCTIONS REFERENCE MANUAL.
All inputs are isolated. C500-IA I/O Unit AC Input 32 pts C500-IA223(3G2A5-IA223).
AC200-240V 10mA.Model : CV500-IPS01.
Input: 100 to 120/200 to 240 VAC Output: 2A, 24 VDCName: Heat/Cool Temperature Control Module.
Model: C200H-TV102.
Sensor: Platinum resistance thermometer: JPt100, Pt100.
Control output: Voltage output(transistor output used for cooling outputs).Name: MIL Connectors.
Specifications: Inputs;
32 inputs ; PNP; --.
"Easy" and "Flexible" system expansion,
with linked CC-Link and CompoNet.
Branching is easily made with CompoNet.
Wiring material cost can be reduced.
Bit-level I/O distribution reduces,
wiring in the system.
A wide variety of CompoNet Slave Units,
contribute to system size reduction.
Seven-segment Display on the Gateway Unit,
helps to detect errors on site.
The Participation Flags and Communications,
Error Flags can be checked at the Host,
Controller to detect the location and,
content of the error. Unit type: CJ1 Special I/O Units.
Product name: Analog Input Unit.
I/O points: 8 inputs;
Signal range selection: 1 to 5 V, 0 to 5 V,
0 to 10 V, -10 to 10 V, 4 to 20mA;
1/4,000(Settable to 1/8,000)*2 .
Conversion period: 1 ms/point,
(250 μs/point can also be set.)*2.
Accuracy at ambient temperature of 25°C:
Voltage: ±0.2% of F. S. Current: ±0.4% of F.S.
External connectioon: Removable terminal block CS1G-CPU44-V1 Manual.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.42A; 24V, --.
Standards: UC1, N, L, CE.
Consistent Microsecond Throughput:
Models with Direct Conversion Join the Lineup.
Anaalog Input Units for converting analog input,
signals into binary data CS1G-CPU44-V1 Manual.
Analog Output Units for converting binary ,
data into analog output signals.