Applicable CPU Units: CQM1H-CPU51/61.
Pulse inputs: 4 inputs.
External outputs: 4 outputS.
Current consumption (Supplied from Power Supply Unit): 5 V DC, 400 mA max.
Dimensions: 25 × 110 × 107 mm (W × H × D).
Weight: 90 g max.
Model: CPM2C-20C1DR-D. CPU Unit: Units with 20 I/O points.
I/O terminal block CS1G-CPU45-V1 INSTRUCTIONS REFERENCE MANUAL.
Inputs: 12 inputs.
Outputs: 8 outputs.
Input type: 24 VDC
CS1G-CPU45-V1
Output type: relay.
Internal clock: Yes.Model : CV500-CN228.
BASIC for connecting the unit ← → FIT10 (2m).Unit type: CJ1 Basic I/O Units.
Product name: Transistor Output Units.
Specifications: Output type, Sinking;
I/O points, 64 outputs;
Maximum switching capacity, 24VDC, 0.3A;
Commons, 16 points, 1 common;
External connection, Fujitsu connector CS1G-CPU45-V1 INSTRUCTIONS REFERENCE MANUAL.
No. of words allocated: 4 words.
Current consumption: 5V, 0.17A; 24V, --.
Standards: UC1, N, L, CE.
A Wide Range of Basic Output,
Units for High Speed Output,
and Different Applications.
These Output Units receive the ,
results of output instructions ,
from the CPU Unit and perform ON/OFF,
control for external devices.
High-speed Output models CJ1W-OD213 and,
CJ1W-OD234 can help to increase system CS1G-CPU45-V1 INSTRUCTIONS REFERENCE MANUAL.
throughput. 1 axis, Pulse output. speeds: 1 to 100, 000 pps.Available on either 3.5” or 5.25” floppy disks.Unit type: CS1 Special I/O Units.
Product name: Isolated-type DC Input Unit.
Input points : 4 inputs.
Signal range: 4 to 20 mA, 0 to 20 mA,
1 to 5 V, 0 to 5 V, ±5 V, 0 to 10 V, ±10 V.
Conversion speed (resolution):
100ms/4 inputs.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.15A; 26V, 0.16A.
Standards: UC1, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in cost and spacee compared,
with previous systems CS1G-CPU45-V1 Manual.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCCUs,
to construct complete process control systems CS1G-CPU45-V1 Manual.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.