Product model: D4N-4E62-SC2
Name: safety limit switch
Brand: OMRON
Sort: INSTRUCTION sheet
File language: English
File size: 0.61MB
Actuator: Adjustable roller lever, form lock (metal lever, rubber roller).
Conduit size: 2-conduit; M20.
Built-in switch mechanism: 2NC (Slow-action).
A Series of Pull-reset Models Now.
Available.
Lineup includes three contact models with 2NC/1NO and 3NC,
contact forms in addition to the previous contact forms 1NC/1NO and 2NC D4N-4E62-SC2 .
M12-connector models are available, saving on labor and,
simplifying replacement D4N-4E62-SC2
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115, EN81-1 and EN81-2.
Certified standards: UL, EN (TÜV), and CCC. Ratings: Standard load; 0.1 A at 125 VAC, 0.1 A at 30 VDC.
Cable: VCTF cable *2 D4N-4E62-SC2 .
Actuator: Roller lever.
Cable length : 5 m.
Compact Limit Switch That''s Also.
Thin and Highly Sealed.
Approved by EN, UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved models.)
Sealing characteristics that meet IEC IP67 degree of protection.
Triple-sealed construction:
Plunger section sealed via nitrile rubber packing seal and,
diaphragm; switch section sealed via nitrile rubber cap;
cable entrance sealed via encapsulating material D4N-4E62-SC2 .
Cable lengths of 3 and 5 m available on standard models.
Models also available with UL and CSA-certified cables.
Multiple mounting possible with Switches with Plungers.
Models with red LED indicators added to series for easy,
confirmation of operation.
(Set by default to light for non-operation.)
VCTF oil-resistant cables with CE marking.
(Applicable only to standard models.)Specifications: Output, PNP (+ common), 8 points.
I/O connections: Sensor I/O connector.
Rated internal circuit power supply voltage:
Supplied from the communications connector.
Rated I/O power supply voltage: 24 VDC.
Environment-resistive (IP67) I/O.
Terminals with Troubleshooting.
Functions such as Sensor Power.
Supply Short-circuit Detection.
Equipped with the standard Smart Slave functions that provide powerful,
preventative maintenance and troubleshooting capabilities.
High ddegree of environmental resistance with dust-proof,
and drip-proofconstruction D4N-4E62-SC2 INSTRUCTION sheet.
Power supply wiring is not required for input devices.
Connect heavy-load devices (up to 1.5 A).
Power supply wiring is not required foor input devices such as sensors D4N-4E62-SC2 INSTRUCTION sheet.
(Power supply wiring is required for output devices.)
Detects ground faults or disconnects and notifies the Master.
Related products
OMRON
Safety Limit Switch
D4N-4E20
OMRON Safety Limit Switch D4N-4E20
Actuator: Roller lever resin lever, resin ro
OMRON
Safety Limit Switch
D4N-4E25
OMRON Safety Limit Switch D4N-4E25
Actuator: Roller lever metal lever, metal ro
OMRON
Safety Limit Switch
D4N-4E26
OMRON Safety Limit Switch D4N-4E26
Actuator: Roller lever metal lever, earing
OMRON
Safety Limit Switch
D4N-4E22
OMRON Safety Limit Switch D4N-4E22
Actuator: Roller lever metal lever, resin ro