LK Automation Limited
Home >> Download >> OMRON >> Manual Download >> OMRON D4N-6D2HR INSTRUCTION sheet

OMRON D4N-6D2HR INSTRUCTION sheet

Product model: D4N-6D2HR
Name: pull-reset safety limit switch
Brand: OMRON
Sort: INSTRUCTION sheet
File language: English
File size: 0.54MB
Receptacle box: G 1/2 Conduit.
Indicator: With LED indicator (DC).
Actuator: Flexible rod, Coil spring.
The Limit Switch with Better Seal,
Shock Resistance, and Strength.
A double seal on the head, a complete gasket cover, and,
other features ensure a better seal (meets UL NEMA 3, 4, 4X, 6P, 12, 13) D4N-6D2HR .
Wide standard operating temperature range:
-40°C to +100°C (standard type).
Models with fluoro-rubber available for greater resistance to chemicals D4N-6D2HR
Block mounting method also reduces downtime for maintenance.
DPDT, double-break models available for complex operations.
Approved by UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved model D4N-6D2HR . ) Ratings: Standard load; 5 A at 250 VAC, 4 A at 30 VDC.
Cable: VCTF cable *2.
Actuator: Pin plunger.
Cable length : 5 m.
Compact Limit Switch That''s Also.
Thin and Highly Sealed.
Approved by EN, UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved models.)
Sealing characteristics that meet IEC IP67 degree of protection.
Triple-sealed construction:
Plunger section sealed via nitrile rubber packing seal and,
diaphragm; switch section sealed via nitrile rubber cap;
cable entrance sealed via encapsulating material D4N-6D2HR .
Cable lengths of 3 and 5 m available on standard models.
Models also available with UL and CSA-certified cables.
Multiple mounting possible with Switches with Plungers.
Models with red LED indicators added to series for easy,
confirmation of operation.
(Set by default to light for non-operation.)
VCTF oil-resistant cables with CE marking.
(Applicable only to standard models.)Ratings: Standard load; 5 A at 125 VAC.
Cable: VCTF cable *2.
Actuator: Pin plunger.
Cable length : 3 m.
Compact Limit Switch That''s Also.
Thin and Highly Sealed.
Approved by EN, UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved models.)
Sealing characteristics that meet IEC IP67 degree of protection.
Triple-sealed construction:
Plunger section sealed via nitrile rubber packing seal and,
diaphragm; switch section sealed via nitrile rubber cap;
cable entrance sealed via encapsulating material.
Cable lengthss of 3 and 5 m available on standard models D4N-6D2HR INSTRUCTION sheet.
Models also available with UL and CSA-certified cables.
Multiple mounting possible with Switches with Plungers.
Models with red LED indicators added to series for easy,
connfirmation of operation D4N-6D2HR INSTRUCTION sheet.
(Set by default to light for non-operation.)
VCTF oil-resistant cables with CE marking.
(Applicable only to standard models.)
Related products
OMRON
Safety Limit Switch
D4N-4D26
OMRON Safety Limit Switch D4N-4D26
Actuator: Roller lever metal lever, earing
OMRON
Pull-reset Safety Limit Switch
D4N-4B32R
OMRON Pull-reset Safety Limit Switch D4N-4B32R
Actuator: Roller plunger. Conduit size: 1-co
OMRON
Safety Limit Switch
D4N-4B87
OMRON Safety Limit Switch D4N-4B87
Actuator: Plastic rod. Conduit size: 1-condu
OMRON
Safety Limit Switch
D4N-1D22
OMRON Safety Limit Switch D4N-1D22
Actuator: Roller lever metal lever, resin ro