Actuator: Adjustable rod lever.
Conduit openings: G1/2 (PF1/2).
1NC/1NO (Snap-action).
Robust safety limit switch with metal housing.
Slow-action and snap-action contact with,
certified direct opening operation certification.
Direct opening mechanism (NC contacts only) added to,
enable opening contacts when faults occur, such as fused contacts D4NL-4AFA-B4 Manual.
Safety of lever settings ensured using a mechanism that,
engages a gear between the operating position indicator plate and the lever
D4NL-4AFA-B4
Equipped with a mechanism that indicates the applicable,
operating zone, as well as push-button switching to control left and right motion.
Head seal structure strengthened to improve seal properties.
(TÜV: IEC IP67, UL: NEMA 3, 4, 4X, 6P, and 13) D4NL-4AFA-B4 Manual.
Wide standard operating temperature range: –40 to 80°C (standard type).
Certified standards: UL, CSA, EN (TÜV), and CCC.
Actuator: Roller plunger (Metal roller).
Cable length: 1 m.
Pull-outing direction of cable: Horizontal.
Built-in switch: 2NC (slow-action).
Smallest Class of Safety Limit Switches the World.
The world''s smallest limit switch with a direct opening,
mechanism (four-contact construction model) D4NL-4AFA-B4 Manual.
High-sensitivity safety limit switch.
Built-in switches with two- or four-contact construction are available.
Degree of protection: IP67.
Conforms to EN115-1, EN81-1 and EN81-2.
(slow-action models only).
Certified standards: UL, EN (TÜV), and CCC OMRON guard lock safety-door switch Manual. Release Key Type: Standard (metal).
Wiring method: Terminal block.
Solenoid voltage/Indicator: 24VDC (Orange) OMRON guard lock safety-door switch Manual.
Lock and release type: Mechanical lock Solenoid release.
Contact configuration (door open/closed detection switch,
and lock monitor switch contacts): 6-contact Model,
Insert the built-in switch (N, P, Q or R) into the blank @.
Conduit size (See Note.): 1/2-14NPT OMRON guard lock safety-door switch Manual.
World''s smallest Class 6-contact Guard Lock.
Safety-door Switch.
.
Wiring time is reduced with two types of wiring.
methods capable of one-touch attachment and removal.
A wide variety of built-in switches can be used for various devices.
(4-, 5-, and 6-contact models are available).
Key holding force of 1,300 N.
It is possible to change the key inserttion point D4NL-4AFA-B4 INSTRUCTION sheet.
without detaching the head.
Drive solenoids directly from the Controller.
.
Lockout Key to prevent workers from becoming.
trapped inside the hazardous area.
The vertical D4SL Guard Lockk Safety-door Switch,
can be easily mounted on 40 × 40 mm aluminum frames D4NL-4AFA-B4 Manual.
The plastic material makes the Slide Key suitable,
for lightweight doors.