Home >> Download >> OMRON >> Manual Download >> OMRON E2CY-C2AF Manual E2CY-C2AF INSTRUCTION sheet

OMRON E2CY-C2AF Manual E2CY-C2AF INSTRUCTION sheet

Product model: E2CY-C2AF
Name: proximity sensor
Brand: OMRON
Sort: INSTRUCTION sheet
File language: English
File size: 2.09MB
Terminal type: Exposed-lead Models.
Protective tubing diameter D (mm): 4.8 dia.
Protective tubing length L: 20cm.
Lead wire type: Heat resistive.
Lead wire length M : 2m.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work E2CY-C2AF INSTRUCTION sheet.
Ideal for the thermal input devices of Temperature Controllers E2CY-C2AF
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Size: 48 x 96mm.
Category: power AC100 ~ 240V with.
Shell color: black.
Control output 1: output unit mode E2CY-C2AF INSTRUCTION sheet.
Control output 2: output unit mode.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: single phase or three phase heater detection function.
Event entry point: 2.
Transfer output: -.
Remote SP:4 to 20mA input.
Communication: RS-232C.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved E2CY-C2AF INSTRUCTION sheet.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm), interactive display PV/SV.
Through the support software (Ver.4.3 CX-Thermo) makes the process of setting management becomes very
Simple use of simple computing functions (AND/OR logic and delay) to set the implementation of flexible contact output.
Through the infrared port can be carried out from the front of the communication.
The control output ON/OFF times counting function can predict the fault of the internal relay off the temperature controller E2CY-C2AF Manual. Appearance: Shielded, M30.
Sensing distance: 8 mm.
Output configuration: DC 2-wire, (3)-(4) pin arrangement.
Model: Operation mode, NO.
Chip-immune Inductive.
Proximity Sensor.
Correct operation eeven with aluminum or iron chips sticking,
to the Sensor E2CY-C2AF Manual.
Only the sensing object is detected.
Pre-wired Smartclick Connector Models also available.