E3Z-T82-G0 detection methods: the firing pattern.
Connection mode: wire lead out type (2m) 3.
Detection range: 30m.
Output mode: PNP output.
Achieve small, long distance, save electricity and
Standard type of photoelectric sensor for energy saving
Sensing method: Through-beam (Emitter + Receiver).
Connection method: Standard M8 connector E2FQ-X10Y1 .
Sensing distance: 10 m.
Model: PNP output .
The Standard for Photoelectric Sensors,
with a Secure Track Record of One,
Million Sold Yearly
E2FQ-X10Y1
Long sensing distance of 30 m for Through-beam Models, 4 m for,
Retro-reflective Models, and 1 m for Diffuse-reflective Models.
Mechanical axis and optical axis offset of less than ±2.5° simplifies,
optical axis adjustment E2FQ-X10Y1 .
High stability with unique algorithm that prevents interference of,
external light. Terminal type: Exposed-lead Models.
Protective tubing diameter D(mm): 1.6 dia.
Protective tubing length L: 15 cm.
Lead wire type: Standard.
Lead wire length M: 4m.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work E2FQ-X10Y1 .
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Appearance: Unshielded, M12.
Sensing distance: 4 mm.
Output configuration: AC 2-wire.
Model: Operation mode, NC.
General-purpose Threaded.
Capacitive Sensor.
Product lineup with M12, M18, and M30 models.
Fixed sensing distance requires no sensitivity adjustment. Size: 48 x 96mm.
Ontology: terminal type, temperature input type.
Type: control output 1 point type (power AC/DC24V).
Shell color: black.
Control output: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
Heater with broken wire, SSR fault, heater over current detection function /ES1B power supply: single phase heater with detection function.
Event input points: -.
Transfer output: -.
Communication: RS-232C.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUUN/STOP, alarm), interactive display PV/SV E2FQ-X10Y1 INSTRUCTION sheet.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which cann display the current value / target / operation E2FQ-X10Y1 INSTRUCTION sheet.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation.