Stability detection without fear of external interference.
Infrared beam design, anti foreign body blocking ability.
Reduce the chance of false action caused by dust and dirt.
Good environmental resistance.
Using a unique optical design, environmental illumination up to 100kLx.
Protection structure to achieve IP67, waterproof and dust E2V-X15B2-M1 INSTRUCTION sheet.
Convenient installation.
3 installation methods for selection
E2V-X15B2-M1 E32-D82F1 type: special beam type; liquid level detection,
Specialty: heat-resistant Teflon packing 200 DEG C,
Bending radius (mm): R40.
Fiber element for meeting diversified needsSize: M12 (Brass); Double; Unshielded.
Sensing distance: 30 mm.
Connecting method (See note 1.): M12 Connector.
Body length: Short E2V-X15B2-M1 INSTRUCTION sheet.
Output configuration: PNP.
Operation mode NO.
A new generation in global applications. Case color: Black.
Control output: Current output.
Control mode *1: Standard or heating/cooling.
No. of auxiliary outputs: 1.
Detection of heater burnout, SSR failure, and heater overcurrent: --.
No. of event inputs: --.
Transfer output *2: Transfer output using control output.
Communi cations: -- E2V-X15B2-M1 INSTRUCTION sheet.
Previous model: Thermocouple input, --;
Resistance thermometer input, --.
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Temperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV.
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
Switch the PV display between three colors.
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs. Control output 1: Voltage output.
Control output 2: --.
Auxiliary output: Three.
Communications: RS-485.
Heater burnout: One.
Event inputs: Two.
Power supply voltage: 24 VAC/VDC.
Large White PV Display That’s Easier to Read.
Easy to Use, from Model Selection to Setup and Opeeration E2V-X15B2-M1 Manual.
A Complete Range of I/O Capacities,
Functions, and Performance.
Handles More Applications.
The white PV display with a height of 15.2 mm improves visibility.
High-speed sampling at 50 ms.
Short body with depth of oonly 60 mm E2V-X15B2-M1 Manual.
Easy connections to a PLC with programless communications.
Use component communications to link Temperature,
Controllers to each other.