Product model: E3S-CL2-C1
Name: photoelectric switch
Brand: OMRON
Sort: INSTRUCTION sheet
File language: English
File size: 0.22MB
Appearance: 4 dia.
Sensing distance: 1.2 mm.
Connecting method: Pre-wired Models (2 m).
Cable specifications: PVC (oil-resistant).
Operation mode: NO.
Wire color /pin arrangement: Brown: +V, Black: Output, Blue: 0 V.
Model: PNP output.
Ultra small size, but surprisingly easy installation!
With the addition of M4, 5 E3S-CL2-C1 INSTRUCTION sheet. 4-dia., 6.5-dia. size, unshielded,
pre-wired connector model, and connector model, a total of,
108 model variations are available E3S-CL2-C1
High-speed response frequency stably detects moving,
objects: 5 kHz max.
Four indicator lamps for easier indicator positioning.
Special mounting brackets reduce time and efforts for,
installation.
Protective Stainless-steel Spiral Tube against wire,
breakage is available (M4, M5 only) E3S-CL2-C1 INSTRUCTION sheet.
Models also available with standard cables that are 5 m long,
or with robot (bending-resistant) cables. Size: Shielded, M8.
Sensing distance: 1.5 mm.
Model: Output configuration: NPN NC.
Highly Durable Proximity Sensor for.
Tough Environments.
Completely stainless-steel housing.
Aluminum chip immunity.
Embedding installation to metal (steel) fittings E3S-CL2-C1 INSTRUCTION sheet.
Chemical resistance certified by Ecolab Europe.
Lineup includes pre-wire models and DC 3-wire NPN output,
models with fluororesin coating. Terminal type: Exposed-lead Models.
Protective tubing diameter D: 3.2 dia.
Protective tubing length L: 35cm.
Lead wire type: Heat resistive.
Lead wire length M: 8m.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Terminal type: Exposed-lead Models.
Protective tubing diameter D (mm): 6.4 dia. .
Protective tubing length L: 20cm.
Lead wire type: Heat resistive.
Lead wire length M : 2m.
A Wide Variety of High-precision.
Temperaature Sensors E3S-CL2-C1 Manual.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Teemperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal E3S-CL2-C1 Manual.
Related products
OMRON
Oil-resistant, Long-range Photoelectric Sensor
E3S-CD11-M1J
OMRON Oil-resistant, Long-range Photoelectric Sensor  E3S-CD11-M1J
Sensing method: Diffuse-reflective. Appearan
OMRON
Oil-resistant, Long-range Photoelectric Sensor
E3S-CD12
OMRON Oil-resistant, Long-range Photoelectric Sensor  E3S-CD12
Sensing method: Diffuse-reflective. Appearan
OMRON
Label sensor
E3S-CD63 Series/E3S-CD68 Series
OMRON Label sensor E3S-CD63 Series/E3S-CD68 Series
OMRONs original new optical structure, the
OMRON
Mounting Brackets
E39-L86
OMRON Mounting Brackets E39-L86
Fitting materials: Stainless steel SUS304.