LK Automation Limited
Home >> Download >> OMRON >> Manual Download >> OMRON E3T-ST31R INSTRUCTION sheet E3T-ST31R Manual

OMRON E3T-ST31R INSTRUCTION sheet E3T-ST31R Manual

Product model: E3T-ST31R
Name: photoelectric sensors
Brand: OMRON
Sort: INSTRUCTION sheet
File language: English
File size: 0.70MB
Size: 48 x 96mm.
Type: power AC/DC24V with.
Shell color: black.
Control output 1: output unit mode.
Control output 2: output unit mode.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: single phase or three phase heater detection function E3T-ST31R INSTRUCTION sheet.
Event entry point: 2.
Transfer output: -.
Remote SP:4 to 20mA input E3T-ST31R
Communication: RS-232C.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms E3T-ST31R INSTRUCTION sheet.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm), interactive display PV/SV.
Through the support software (Ver.4.3 CX-Thermo) makes the process of setting management becomes very
Simple use of simple computing functions (AND/OR logic and delay) to set the implementation of flexible contact output E3T-ST31R INSTRUCTION sheet.
Through the infrared port can be carried out from the front of the communication.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller. Size: 96 x 96mm.
Type: power AC/DC24V with.
Shell color: black.
Control output 1: output unit mode.
Control output 2: output unit mode.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
The detection function of the broken wire and SSR fault of heater: detection function of single phase or three phase heater.
Event entry point: 2.
Transfer output: -.
Remote SP:4 to 20mA input.
Communication: RS-422.
General thermostat new high performance (high resolution, high speed, high precision input) type products.
Support simple operation, preventive maintenance.
A new type of liquid crystal, which can communicate with the front through the infrared port, is adopted,
Visual angle, contrast can be improved.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV status display function, convenient to checkk the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV E3T-ST31R Manual.
By supporting software (Ver.4.0 CX-Thermo) to carry out a simple function (AND/OR logic and delay),
Be able to execute flexible contact output E3T-ST31R Manual.
Increase the control output ON/OFF number counting function, can predict the temperature controller internal relay fault.
Position ratio type.
Related products
OMRON
Photoelectric Sensors
E3T-SL23
OMRON Photoelectric Sensors E3T-SL23
Sensing method: Convergent-reflective. Conne
OMRON
Photoelectric Sensors
E3T-FT23
OMRON Photoelectric Sensors E3T-FT23
Sensing method: Through-eam Emitter Recei
OMRON
Mounting Brackets
E39-S63
OMRON Mounting Brackets E39-S63
Slit width: 0.5-mm dia., 1 mm. Installation
OMRON
Photoelectric Sensors
E3T-FD12
OMRON Photoelectric Sensors E3T-FD12
Sensing method: Diffuse-reflective. Connecti