Ontology: program type.
Size: 48 x 96mm.
Type: control valve control type (1 input).
Control mode: 1 channel position ratio control.
Output (control / transfer) points: relay output (open 1 + 1) + current 1.
Output (SUB) points: 4 points.
Event input points: -.
Serial communication: RS-485.
New high speed, high precision digital regulator (Cheng Xuxing)!
Can be set up to 32 kinds of procedures E3Z-G61
E3Z-G61
1 units can be coordinated to run up to 4 channels.
High speed acquisition of 50ms.
With CX-Thermo on the computer easily set. Name: Temperature Controller (See note 1.).
Power supply: 24 VDC.
No. of control points: 2.
Control output: Voltage output (for SSRs).
Auxiliary output: Transistor output: 2 pts (sinking) E3Z-G61 .
Functions: Heater burnout alarm (See note 3.), Heating or heat/cool,
control is selectable (See note 4.)Event input: 1 point per Unit.
Communications functions: RS-485.
Input type (See note 5.): Thermocouple.
New DIN Track Mounting Temperature.
Controller.
Two channels of temperature control available despite width of,
only 22.5 mm.
The Temperature Controller itself can be replaced without,
changing terminal wiring E3Z-G61 .
Use in combination with a compact Setting Display Unit to,
reduce communications programming requirements.
Front-panel LED indicators for easy operation monitoring.
Power supply and communications wiring not required between,
Units when mounted side-by-side.
CompoWay/F communications protocol supported.
UL, CSA, and CE Marking compliance. Size: 96 x 96mm.
Category: power AC100 ~ 240V with.
Shell color: black.
Control output 1: output unit mode.
Control output 2: output unit mode.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: single phase or three phase heater detection function.
Event entry point: 2.
Transfer output: -.
Remote SP:4 to 20mA input.
Communication: RS-232C.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm), interactive display PV/SV.
Through the support software (Ver.4.3 CX-Thermo) makes tthe process of setting management becomes very
Simple use of simple computing functions (AND/OR logic and delay) to set the implementation of flexible contact output E3Z-G61 INSTRUCTION sheet.
Through the infrared port can be carried out from the frront of the communication E3Z-G61 INSTRUCTION sheet.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller.