Product model: E3Z-LL86
Name: photoelectric sensors
Brand: OMRON
Sort: INSTRUCTION sheet
File language: English
File size: 0.96MB
Size: 48 x 96mm.
Ontology: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 1 points.
A power supply for the detection of /ES1B fault, SSR fault and heater over current for heater use E3Z-LL86 INSTRUCTION sheet E3Z-LL86
Event input points: -.
Transfer output: -.
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of /.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV E3Z-LL86 INSTRUCTION sheet.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which can display the current value / target / operation.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc E3Z-LL86 INSTRUCTION sheet. , can be a key operation. Size: 96 x 96mm.
Control output 1: current.
Auxiliary (alarm) output: 4.
Transfer output: -.
Event input: 2.
Communication: RS-485.
Disconnection detection: 1.
Power supply voltage: AC100 ~ 240V.
E5 - C series of new products program.
Maximum 256 segment of the program capacity,
Support for multiple applications.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
The use of high 25mm (E5AC-T), 18mm (E5AC-T) PV display (white),
Improve visibility.
Not only on the top of the body, but also on the front,
The use of communication adapter cable (sold separately) connected to the computer after,
No power connection can be set.
It can be easily set by CX-Thermo (sold separately).
High speed samplingg to achieve 50ms E3Z-LL86 Manual.
With auxiliary output (4 points), event input (maximum 6 points), the transmission output,
Support a variety of applications.
Slender fuselage depth 60mm.
Easy to connect with PLC through no program communicatiion E3Z-LL86 Manual.
Combined temperature control device through component communication.
Add position proportional control type, also support control valve control.
Related products
OMRON
Compact Photoelectric Sensor
E3Z-T61K
OMRON Compact Photoelectric Sensor E3Z-T61K
Sensing method: Through-eam Emitter Recei
OMRON
Compact Photoelectric Sensor
E3Z-T61
OMRON Compact Photoelectric Sensor E3Z-T61
Sensing method: Through-eam Emitter Recei
OMRON
Compact Photoelectric Sensor
E3Z-T66
OMRON Compact Photoelectric Sensor E3Z-T66
Sensing method: Through-eam Emitter Recei