Product model: E3ZM-T86
Name: photoelectric sensors
Brand: OMRON
Sort: INSTRUCTION sheet
File language: English
File size: 22.48MB
Size: 48 x 96mm.
Control output 1: relay output.
Control output 2:--.
Auxiliary output: 4 points (auxiliary output 2, 1 common, auxiliary output 3, 4 public general).
Power supply voltage: AC/DC24V.
Terminal shape: screw terminal table type.
Input category: full range multi input.
Heating wire break, SSR fault detection function: - E3ZM-T86 INSTRUCTION sheet.
Communication: -.
Event input: - E3ZM-T86
Remote SP input: -.
Transfer output: -.
Large screen display white PV legible. From selection to setting and operation are simple and easy to use.
Full capacity, function and performance of I/O. Suitable for more applications.
E5AC white LCDPV display height is about 25mm.
The upper panel and the front panel are equipped with tool ports E3ZM-T86 INSTRUCTION sheet.
With the communication conversion line (sold separately) connected to the computer to establish the controller without the need to install the wire for power supply.
Easy to install CX-Thermo (sold separately).
50ms high speed sampling period.
Model can be equipped with up to 4 point auxiliary output, 6 point event input,
1 point transfer output and remote SP input, suitable for a wide range of applications E3ZM-T86 INSTRUCTION sheet.
The main body is short, the thickness is only 60mm.
Easy to use programmable logic controller (PLC) is connected to the programmable logic controller (PLC).
The temperature controller is connected to each other by using the component communication.
A new type of proportional control allows you to control the valve. Size: 48 * 48mm, terminal type.
Type: control output 1 point type (power AC/DC24V).
Shell color: black.
Control output: linear voltage output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: -.
Event entry point: 2.
Transfer output: output (using control output).
Communication: -.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C (to achieve a small size of 48 x 48mm).
High speed sampling period 60ms.
Full of all models (capable of thermocouple /Pt/ analog input switching),
1 machines to support a variety of sensors.
Add PV/SV state display function, to see the statee of the thermostat
(automatic / manual, RUN/RESET, alarm),
Interactive display PV/SV E3ZM-T86 Manual.
By supporting software (Ver.4.3 CX-Thermo),
In simple arithmetic functions (AND/OR logic and delay).
Setting the program settings that can performm flexible contact output E3ZM-T86 Manual.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller.
Related products
OMRON
Compact Photoelectric Sensor
E3ZM-LS81H
OMRON Compact Photoelectric Sensor  E3ZM-LS81H
Sensing method: BGS reflective fixed distanc
OMRON
Compact Photoelectric Sensor
E3ZM-LS62H
OMRON Compact Photoelectric Sensor  E3ZM-LS62H
Sensing method: BGS reflective fixed distanc
OMRON
Compact Photoelectric Sensor
E3ZM-LS67H
OMRON Compact Photoelectric Sensor  E3ZM-LS67H
Sensing method: BGS reflective fixed distanc
OMRON
Compact Photoelectric Sensor
E3Z-T86A
OMRON Compact Photoelectric Sensor E3Z-T86A
Sensing method: Through-eam Emitter Recei