Appearance: Shielded, M18.
Sensing distance: 8 mm.
Output: NPN.
Model: Operation mode NC.
Aluminum and Iron Both.
Detectable from Long Distances. Size: 48 x 96mm.
Ontology: terminal type, temperature input type.
Type: control output 1 point type (power AC/DC24V).
Shell color: black.
Control output: relay output E5AC-CX2ASM-005 INSTRUCTION Manual.
Control mode: standard or heating cooling.
Auxiliary output points: 3 points E5AC-CX2ASM-005
Heater with broken wire, SSR fault, heater over current detection function /ES1B power supply: single phase heater with detection function.
Event entry point: 2.
Transfer output: -.
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of / E5AC-CX2ASM-005 INSTRUCTION Manual.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay E5AC-CX2ASM-005 INSTRUCTION Manual.
Increased the 3 segment display, which can display the current value / target / operation.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation. The main body: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
The heater is used to break, SSR fault, heater over current detection function /ES1B power supply: single phase or three phase heater with detection function.
Event input points: -.
Transfer output: -.
Communication: RS-485.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventive maintenance function is increased,
Furtherr performance improvement E5AC-CX2ASM-005 Manual.
E5CN-U (insert type) add analog input and current output type.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactivee display PV/SV E5AC-CX2ASM-005 Manual.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Related products
OMRON
Digital temperature controller
E5AC-CX2DSM-013
OMRON Digital temperature controller E5AC-CX2DSM-013
Size: 96 x 96mm. Control output 1: linear cu
OMRON
Digital Temperature Controller
E5AC-CX1DSM-800
OMRON Digital Temperature Controller E5AC-CX1DSM-800
Control output 1: Linear current output. Con
OMRON
Digital Temperature Controller
E5AC-CX3DSM-800
OMRON Digital Temperature Controller E5AC-CX3DSM-800
Control output 1: Linear current output. Con
OMRON
Digital temperature controller
E5CC-CX3ASM-005
OMRON Digital temperature controller E5CC-CX3ASM-005
Size: 48 x 48mm. Control output 1: linear cu