Fitting materials: Stainless steel(SUS304).
Count: 1 .
Accessories: Description, Phillips screw Nut plat;
Material, Stainless steel Stainless steel;
Count, 2, 1.
Applicable sensor (mounting pitch on sensor side): E3NC-LH03.
Page: Dimensions, 16. Size: M12 (Brass); Single; Shielded.
Sensing distance: 10 mm E5AC-QX4ASM-012 INSTRUCTION Manual.
Connecting method (See note 1.): M12 Connector
E5AC-QX4ASM-012
Body length: Long.
Output configuration: PNP.
Operation mode NC.
A new generation in global applications. Size: 48 x 48mm.
Body: terminal type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: silver.
Control output: voltage output (SSR driver).
Control mode: standard or heating cooling.
Auxiliary output points: 2 points E5AC-QX4ASM-012 INSTRUCTION Manual.
SSR fault detection function for heater with broken line: detection function for single phase heater.
Event input points: -.
Transfer output: -.
Communication: RS-485.
General thermostat new high performance (high resolution, high speed, high precision input) type products.
Support simple operation, preventive maintenance, using a new type of liquid crystal, visual angle, contrast to enhance E5AC-QX4ASM-012 INSTRUCTION Manual.
High resolution 5 bit display / can display 0.01 degrees C (to achieve a small size of 48 x 48mm).
High speed sampling period 60ms.
All models (thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Add PV/SV state display function, to see the state of the thermostat.
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
By supporting software (CX-ThermoVer.4.0) to carry out a simple function (AND/OR logic and delay),
Be able to execute flexible contact output
Increase the control output ON/OFF number counting function, can predict the temperature controller internal relay faultE3JK-R2S3 detection method: Regression reflection type with M.S.R. function,
Connection mode: lead wire,
Detection range: 2.5m.
Output state: when the light into the ON; light shading ON.
Output: DC no contact,
2 types of cost reductionTerminal type: Exposed-lead Models.
Protective tubing diameter D: 3.2 dia.
Protective tubing length L: 35cm.
Lead wire type: Standard.
Lead wire length M: 2m.
A Wide Variety of High-precision.
Temperature Sensors E5AC-QX4ASM-012 Manual.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Teemperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal E5AC-QX4ASM-012 Manual.