Sensing method: Through-beam.
Connection method: Pre-wired (2 m).
Sensing distance: 300 mm.
Operation mode: Dark-ON.
Model: NPN output.
Makes Mounting and Installation Simpler and Smoother.
Suitable for Applications in the Rechargeable Battery Industry. Size: 48 * 48mm, terminal type.
Category: control output 1 point type (power supply AC100 ~ 240V) E5EC-CX4ASM-004 Manual.
Shell color: black
E5EC-CX4ASM-004
Control output: relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: single phase heater detection function.
Event entry point: 2.
Transfer output: -.
Communication: -.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved E5EC-CX4ASM-004 Manual.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C (to achieve a small size of 48 x 48mm).
High speed sampling period 60ms.
Full of all models (capable of thermocouple /Pt/ analog input switching),
1 machines to support a variety of sensors.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm),
Interactive display PV/SV E5EC-CX4ASM-004 Manual.
By supporting software (Ver.4.3 CX-Thermo),
In simple arithmetic functions (AND/OR logic and delay).
Setting the program settings that can perform flexible contact output OMRON digital controller Manual.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller OMRON digital controller Manual. Item: Advanced models, Twin-output model.
Functions: Area output, open circuit detection, differential operation.
Communications Unit Applicable Sensor: E3X-ECT, E3X-CRT.
Proximity Sensor with Separate.
Amplifier Enables Easily Making High.
precision Sensitivity Settings OMRON digital controller Manual.
Wide variety of Sensor Heads to select according to the,
application. Flexible cables are used between Preamplifiers,
and Amplifier Units of the Sensor Heads.
High resistance to changes in ambient temperature.
Temperature characteristics of 0.08%/°C (for 5.4-dia. modelss) E5EC-CX4ASM-004 INSTRUCTION Manual.
Make simple and reliable detection settings with micron,
level precision using the teaching function.
Check the sensing excess gain level on the digital display.
Support for high-precision positioning and screening witth,
fine positioning to maximize variations E5EC-CX4ASM-004 Manual.
The E2C-EDA0 supports an EtherCAT Sensor,
Communications Unit or CompoNet Sensor,
Communications Unit.