Product model: E5EN-C3BTD-N
Name: Temperature Controller
Brand: OMRON
Sort: Communications Functions User's Manual
File language: English
File size: 0.55MB
Terminal type: Exposed-lead Models.
Protective tubing diameter D (mm): 1 dia.
Protective tubing length L: 15 cm.
Lead wire type: Heat resistive.
Lead wire length M : 2m.
A Wide Variety of High-precision.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work E5EN-C3BTD-N Communications Functions.
Ideal for the thermal input devices of Temperature Controllers E5EN-C3BTD-N
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal. Size: 48 x 96mm.
Ontology: terminal type, analog input type.
Category: control output 1 point type (power supply AC100 ~ 240V) E5EN-C3BTD-N Communications Functions.
Shell color: black.
Control output: relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 3 points.
Heater with broken wire, SSR fault, heater over current detection function /ES1B power supply: single phase heater with detection function.
Event entry point: 2.
Transfer output: -.
Communication: -.
The general temperature controller 96mm, 48 * 96mm square has been upgraded to improve the performance and function of / E5EN-C3BTD-N Communications Functions.
Indicates that the accuracy of the upgrade, increase the function of prevention and maintenance, further enhance the performance.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay.
Increased the 3 segment display, which can display the current value / target / operation.
Increased the PF key, the distribution of automatic / manual, RUN/STOP, etc., can be a key operation. Control output 1: Relay output.
Control output 2: --.
Auxiliary output: Three.
Communications: --.
Heater burnout: One.
Event inputs: Four.
Power supply voltage: 100 to 240 VAC.
Large White PV Display That’s Easier to Read.
Easy to Use, from Model Selection to Setup and Operation. E5EN-C3BTD-N User's Manual.
A Complete Range of I/O Capacities,
Functions, and Performance.
Handles More Applications.
The white PV display with a height of 15.2 mm improves visibility.
High-speed sampling at 50 ms.
Short body with depth of oonly 60 mm E5EN-C3BTD-N User's Manual.
Easy connections to a PLC with programless communications.
Use component communications to link Temperature,
Controllers to each other.
Related products
OMRON
Foundation type temperature controller
E5EN-C301TD-FLK-N
OMRON Foundation type temperature controller E5EN-C301TD-FLK-N
Size: 48 x 96mm. Ontology: terminal type, tem
OMRON
Foundation type temperature controller
E5EN-CY3BT-N
OMRON Foundation type temperature controller E5EN-CY3BT-N
Size: 48 x 96mm. Ontology: terminal type, tem
OMRON
Foundation type temperature controller
E5EN-C3BBL-N
OMRON Foundation type temperature controller E5EN-C3BBL-N
Size: 48 x 96mm. Ontology: terminal type, ana
OMRON
Foundation type temperature controller
E5EN-C1T-W-N
OMRON Foundation type temperature controller E5EN-C1T-W-N
Size: 48 x 96mm. Ontology: terminal type, tem