Size: M30, Non-shielded.
Sensing distance: 20.0 mm.
Connection: Pre-wired.
Body material: Brass.
Thread length (overall length): 44 (64)(See note.).
Output configuration: NPN.
Operation mode NO.
Safe Mounting with Greater.
Sensing Distance.
Ensures a sensing distance approximately 1.5 to 2,
times larger than that of any conventional OMRON Sensor EE-SX676P-C1J-R INSTRUCTION sheet.
Problems such as the collision of workpieces are eliminated
EE-SX676P-C1J-R
Full range of standard sizes (M8, M12, M18 and,
M30; both long and short barrels).
Modular construction simplifies customization. Size: 48 x 96mm.
Category: power AC100 ~ 240V with.
Shell color: black.
Control output 1: position ratio with relay output.
Control output 2: position ratio with relay output EE-SX676P-C1J-R INSTRUCTION sheet.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: single phase or three phase heater detection function.
Event entry point: 4.
Transfer output: -.
Remote SP:4 to 20mA input.
Communication: -.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved EE-SX676P-C1J-R INSTRUCTION sheet.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm), interactive display PV/SV.
Through the support software (Ver.4.3 CX-Thermo) makes the process of setting management becomes very
Simple use of simple computing functions (AND/OR logic and delay) to set the implementation of flexible contact output.
Through the infrared port can be carried out from the front of the communication.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller. Sensing method: Narrow-beam reflective.
Connection method: Connector (M8, 4pins).
Sensing distance: 90±30 mm.
Model: NPN output.
Small 2.5-mmm-diameter Spot Ideal for EE-SX676P-C1J-R Manual.
Detecting Small Workpieces.
Tiny workpieces as little as 0.1 mm in diameter can be,
detected with the 2.5-mm-dia. spot.
The narrow beam enables sensing from small slots or holes.
The small spott of light enables visual checking of sensing,
spot position EE-SX676P-C1J-R Manual.
IP67 degree of protection, mutual interference prevention,
and EN standard compliance.