Classification: Totalizing Counter.
Input signal system (Count & reset inputs): Contact/Transistor.
Mounting method: Flush mounting, surface mounting.
Display: 7-segment LEDs (10 mm high).
Number of digits: 4 digits (0 to 9,999).
Backup power for memory protection: Yes.
Control output: --.
Operating mode: Up counting H3AM-NS-A .
Max.counting speed: 5 kcps (see note 1.).
All Required Counter Functions
H3AM-NS-A
Incorporated in a Compact DIN-sized.
(48 × 48) Housing.
In addition to Up and Down models, a reversible (Up-Down),
counter is also available.
Maximum counting speed of 5,000 cps, never before attained by,
a small-size preset counter.
Power supply freely selectable within a range of 100 to 240 VAC H3AM-NS-A .
Also, power supply for the DC-operated models is selectable,
within a range of 12 to 48 V.
Models with memory backup function against power failure available. Count input: PNP/NPN universal DC voltage input(4.5 to 30 VDC).
Max. counting speed: 30 Hz ←→ 1 kHz(switchable).
Display: 7-segment LCD with backlight.
Model: Light-gray body.
Eight-digits, counting range 0 to 99999999.
Dual input speed: 30 Hz ←→ 1 kHz,
(except for AC/DC multivoltage input models) H3AM-NS-A . Control output: Time-limit SPDT and Instantaneous SPDT.
Supply voltage: 24 VDC.
Solid-state Timer with Single Time Range.
and Operating Mode.
Time range: H3BA-X8HA (0.05 s to 12 h),
H3BA-X8HB (0.3 s to 30 h),
H3BA-X8HC (0.6 s to 60 h).
Operating mode: ON-delay only.
Pin type: 8-pin only. Rated supply voltage: 100 to 240 VAC.
Resetting system (See note.): Self-resetting.
Control output: DPDT contact output (Time-limit output SPDT,
and switchable SPDT(time-limit - instantaneous)).
Time range: 1 s to 60 h (60 s, 6 min, 60 min, 6 h, 60 h).
Large Setting Dial and Moving Pointers Ideal,
for Easy Operation and Monitoring.
Incorporating an easy-to-see large setting dial with moving pointers.
Wide time-setting range of 0.2 s to 60 h.
(available through three time-range model types).
Wide AC power supply range (100 to 240 VAC).
IP65 watertight and dust-tight front panel.
Approved by UL and CSA.
Conforms to EN61812-1 and IEC60664-1.
4 kV for Low Voltage, and EMC Dirrectives H3AM-NS-A INSTRUCTION MANUAL.
Conforms to EMC standards.
Six-language instruction manual provided.
Programmable contact enables the building of a self-holding,
relay circuit as well as built-in instantaneous contact. (-NS).
Memory reteention (-NSR) H3AM-NS-A INSTRUCTION MANUAL.
Finger protection terminal block.
Enables easy sequence checks through instantaneous outputs.
for a zero set value at any time range.