Product model: FX2N-16MR-D
Name: PLC
Brand: MITSUBISHI
Sort: PROGRAMMING MANUAL II
File language: English
File size: 7.09MB
Input and output points: 14 points.
Power supply: DC24V.
Input points: 8 points.
Output points: 6 points.
Output form: transistor output (drain).
Power consumption: 19W.
Weight: 0.5KG.
Outline dimension: 90x90x86mm.
A free combination of PLC.
FX3G basic unit: 14/24/40/60 point.
FX3GA is a compact PLC, simple design and with the basic functions of the FX3 series FX2N-16MR-D Manual.
Through the strengthening of the built-in function and flexible expansion, expanded in various fields of application FX2N-16MR-D
Third generation standard model.
High flexibility.
Suitable for small scale control of high cost.
Control points to 128 points, the use of CC-Link remote I/O can control the maximum 256 points.
High speed operation.
Basic instructions: 0 FX2N-16MR-D Manual. 21 s/ instruction.
Application instruction: 0.5 s/ instruction.
Large capacity memory.
Built in program memory 32000 steps.
EEPROM memory cartridge with program transfer function.
Third generation standard model.
Easy to use integrated models and flexible scalability.
Condensed convenience of using the usual FX3 series.
Its high price by the most suitable for small scale control FX2N-16MR-D Manual. MITSUBISHI inverter FR-A740 series.
Voltage level: 3 phase 400V.
Frequency converter capacity: 45KW.
Frequency converter is the application of frequency conversion technology and micro electronics technology, by changing the motor operating power frequency mode to control the AC motor power control equipment MITSUBISHI FX2N-16MR-D PROGRAMMING MANUAL II.
The converter is composed of rectifier (AC), filter, inverter (DC), braking unit, driving unit, micro processing unit of the detection unit MITSUBISHI FX2N-16MR-D PROGRAMMING MANUAL II.
Inverter by the internal IGBT to adjust the output power supply voltage and frequency,
According to the actual needs of the motor to provide the required power supply voltage, and then achieve the purpose of energy saving, speed control, in addition to the,
Inverter has a lot of protection functions, such as over current, over voltage, overload protection and so on MITSUBISHI FX2N-16MR-D PROGRAMMING MANUAL II. Length: 1.5m.
Specification: TB-FX round cable. Adapter RS-485 communication (FX3U- - racy -BD)"MITSUBISHI inverter FR-F720P series.
Voltage level: three phase 200V.
Frequency converter capacity: 3.7KW.
When the inverter is running, the starting current and starting torque of the motor are how?
With the operation of the inverter, with the acceleration of the motor to improve the frequency and voltage,
The starting current is limited to 150% below the rated current (according to the different types of aircraft, 125%~200%).
It is based on the overall effect of three-phase waveform generation,
In order to approach the ideal circular rotating magnetic field in the air gap of the motor,
A generation phase modulation waveform control inscribesthe polygon to approach the circle way.
After practice, it has been improved, that is, the introduction of frequency compensation, can eliminate the error of speed control;
By feedback estimation of flux amplitude, eliminating the influence of stator resistance at low speed, the output voltage and current closed loop,
In order to improve the accuracy and stability of the dynamic.
But there are many control circuit, and no torque is introduced, so the system performance has not been improved.
Frequency converter is a power control device which uses the power of the power semiconductor device to change the power frequency to another frequency,
Can realize the asynchronous motor soft start, variable frequency speed regulation, improve the operation precision, change the power factor, over current / over voltage / overload protection and other functions.
The use of frequency converter motor is in order to speed, and reduce the starting current.
In order to produce a variable voltage and frequency,
The equipment to the power of the AC power conversion to DC (DC), the process is called rectification.
The direct current (DC) is transformed into alternating current (AC) and its scientific term is "inverter" (inverter).
General inverter is the DC power supply inverter for a certain fixed frequency and a certain voltage of the inverter.
For the inverter as the frequency adjustable, adjustable voltage inverter, we called the inverter.
Inverter output waveform is simulated sine wave,
Is mainly used in three-phase asynchronous motor speed control, and also called frequency governor.
For the variable frequency inverter, which iss mainly used in the testing equipment of instrument and meter,
To sort out the waveform, you can output the standard sine wave, called the inverter power supply FX2N-16MR-D .
The general inverter is 1520 times inverter price.
The main device called "inverter" because of the voltage or frequency of the inverter device ",
Therefore, the product itself is named "inverter", that is: inverter FX2N-16MR-D Manual. "
Related products
MITSUBISHI
PLC
FX2N-16MR-001
MITSUBISHI PLC FX2N-16MR-001
Max input / output points: 16 points. Supply
MITSUBISHI
Input module
FX2N-8EX
MITSUBISHI Input module FX2N-8EX
Total input and output points: 8 points. Inpu
MITSUBISHI
PLC
FX2N-64MS
MITSUBISHI PLC FX2N-64MS
Max input / output points: 64 points. Supply
MITSUBISHI
Transistor output unit
FX2N-48ET-D
MITSUBISHI Transistor output unit FX2N-48ET-D
Total input and output points: 48 points. Inp