LK Automation Limited
Home >> Download >> MITSUBISHI >> Manual Download >> PLC Q01UCPU MELSAP-L Programming Manual MITSUBISHI Q01UCPU Manual

PLC Q01UCPU MELSAP-L Programming Manual MITSUBISHI Q01UCPU Manual

Product model: Q01UCPU
Name: PLC
Brand: MITSUBISHI
Sort: MELSAP-L Programming Manual
File language: English
File size: 3.16MB
SRAM+E2PROM memory card.
RAM capacity: 512KB.
E2PROM capacity: 512KB. 4 axes, open collector output type.
Control unit: pulse.
Location data: 10 data / axis.
Maximum pulse output: 200Kpps.
40 pin connector.
Ideal solution for simple multi axis positioning.
Perfect match with stepper motor control.
Plus deceleration smooth, speed change subtle Q01UCPU Programming Manual.
To speed up the speed of positioning control to start processing Q01UCPU
Positioning module.
Open collector output.
Differential driver output.
Based on the use of open collector outputs and differential drive output type 2 types.
Differential driver output type positioning module can transmit high speed instruction pulse (up to 4Mpps) to the servo amplifier reliably,
Transmission distance of up to 10 meters, to achieve high speed and high precision control Q01UCPU Programming Manual.
(the command pulse of the open collector positioning module is highest 200kpps.)
Reduce system downtime recovery time.
With a simple operation, you can back up all the data in the CPU to the memory card.
Through regular backup, can be the latest parameters, procedures, etc. to save the storage card Q01UCPU Programming Manual.
In the event of a CPU failure, after the replacement of CPU, can be a simple operation,
Restore the system by using the data storage card in advance.
Therefore, it is not necessary to spend time to manage the backup data, but also can shorten the recovery time of the system shutdown MITSUBISHI Q01UCPU Manual. PCI bus.
Support Japanese, English OS.
3C-2V/5C-2V coaxial cable.
Single bus controller network (control station / common station) MITSUBISHI Q01UCPU Manual.
Province distribution network module in cabinet and device.
Link to connect the 64 stations when the fastest scanning time for 1.2ms (rate 2.5Mbps).
According to the transmission distance, the transmission rate is selected from 2.5Mbps, 625kbps and 156kbps MITSUBISHI Q01UCPU Manual.
CC-Link/LT from the station does not need any parameter settings.
Only need to set up the transmission speed in the master module, you can use the remote I/O.
I/O control in the first class of open field network module.
CC-Link based on reliable field bus technology,
Able to transmitt large number of bits data (such as ON/OFF information) and word data (such as analog information) Q01UCPU MELSAP-L.
Consistency of CC-Link to maintain loop transmission,
And the cycle of transmission and information (instantaneous transmmission) communication separately, so as to ensure the timeliness of Q01UCPU Programming Manual.
Even if the information reaches saturation, it will not affect the link scan time.
Related products
MITSUBISHI
CPU unit
A0J2HCPU
MITSUBISHI CPU unit A0J2HCPU
Input and output points: 480 points. Input /
MITSUBISHI
Programmable logic controller CPU
R16ENCPU
MITSUBISHI Programmable logic controller CPU R16ENCPU
Operation control mode: stored procedure repe
MITSUBISHI
General purpose CPU
Q06UDHCPU
MITSUBISHI General purpose CPU Q06UDHCPU
Input / output points: 4096 points. Numer of
MITSUBISHI
CPU unit
A3VCPU
MITSUBISHI CPU unit A3VCPU
Multiple CPU units for A3VTS multiplex system