LK Automation Limited
Home >> Download >> MITSUBISHI >> Manual Download >> PLC Q02UCPU Application Functions Manual MITSUBISHI Q02UCPU Programming Manual

PLC Q02UCPU Application Functions Manual MITSUBISHI Q02UCPU Programming Manual

Product model: Q02UCPU
Name: PLC
Brand: MITSUBISHI
Sort: Application Functions Programming Manual
File language: English
File size: 5.25MB
Master / local station sharing.
IE CC-Link field network.
Make the mixed data environment intelligent, to achieve a new manufacturing system IE CC-Link field network module.
Using Ethernet cables and connectors available on the market to reduce costs.
High speed communication capable of communicating with 1Gbps Q02UCPU Manual.
Improve the communication response, significantly shorten the cycle time Q02UCPU
Improve the performance of cycle data update. Reduces the transmission delay time and the application of the synchronization waiting time.
Data can be read or written to other station programmable controller.
Status of IE CC-Link field network can be confirmed by Works2 GX.
Can be in the Works2 GX up and down the abnormal position, the cause of the exception, the event record,
So it can reduce the time of abnormal to resume normal operation Q02UCPU Manual.
QJ71GF11-T2 can be used as the main station / local station of IE CC-Link field network.Input and output points: 1024 points.
Input / output data points: 8192 points.
Program capacity: 60k.
Basic command processing speed (LD command) S:0.075.
PLC in the program execution stage: according to the order of the user program order to store the order of each instruction,
After the corresponding operation and processing, the result is written to the output status register,
The contents of the output status register are changed with the execution of the program Q02UCPU Manual MITSUBISHI Q02UCPU Programming Manual.
Output refresh phase: when all instructions are executed,
The output status register is sent to the output latch in the output refresh stage,
And through a certain way (relay, transistor or transistor) output, drive the corresponding output equipment MITSUBISHI Q02UCPU Programming Manual. Extended SRAM card 8MB
To record the change of control data without missing.
Data can be collected in a time interval or in a millisecond time interval,
To record the change of the specified control data without any omission MITSUBISHI Q02UCPU Programming Manual.
Therefore, in the event of failure, can quickly determine the cause, the precise action analysis.The bus can be equipped with Q series CPU module, interrupt module.
16 point.
DC24V.
Response time: 0.1/0.2/0.4/0.6/1ms.
16 point / common end.
Positive common end.
18 point terminal.
Continue to go beyond, to climb the peak of Q series.
Strengthen security function.
Can be set up to 32 characters of the file password.
In addition to the English letters, numbers, but also the use of special characters,
To further enhance the security of the password.
In addition, only pre registered devices are allowed to access CPU,
To intercept unauthorized access to unauthorized users.
Therefore, it is important to prevent the outflow of important program assets and protect intellectual property rights.
A variety of modules with excellent performance,
Meet the needs of various control from analog to location.
Q series module products include a variety of types of I/O, analog and positioning function module.
Can fully meet the switch, sensor, such as the input and output, temperature, weight, flow and motor, drive control,
As well as the requirements of high-precision control of the positioning of the industry, the control needs of various fields.
Can also be used in combination with the CPU module to achieve appropriate control.
Easy connection programming tool via ethernet.
Programming tools (Woorks2 GX, Developer GX) and CPU direct connection (1 to 1),
No need to carry out the IP address settings Q02UCPU Application Functions. And there is no need to select the cable, the straight line and the cross line can be used.
Therefore, this connection method annd the use of USB, can easily communicate with the CPU,
Even the operators are not familiar with the network settings can easily establish a connection Q02UCPU Manual.
Related products
MITSUBISHI
With Ethernet CPU
Q04UDEHCPU
MITSUBISHI With Ethernet CPU Q04UDEHCPU
Input / output points: 4096 points. Numer of
MITSUBISHI
CPU component
A1SHCPU
MITSUBISHI CPU component A1SHCPU
I/O control method: refresh mode or direct mo
MITSUBISHI
High performance CPU
Q02CPU
MITSUBISHI High performance CPU Q02CPU
Program capacity: 28K step. Input / output po