LK Automation Limited
Home >> Download >> MITSUBISHI >> Manual Download >> PLC Q100UDEHCPU Common Instructions Manual MITSUBISHI Q100UDEHCPU Programming Manual

PLC Q100UDEHCPU Common Instructions Manual MITSUBISHI Q100UDEHCPU Programming Manual

Product model: Q100UDEHCPU
Name: PLC
Brand: MITSUBISHI
Sort: Common Instructions Programming Manual
File language: English
File size: 19.95MB
ABS serial synchronous encoder input can be used: 2 sets of modules / units.
Position detection method: compiled on value (ABS) method.
Transmission mode: serial communication.
Allows you to track target input points: 2.
Convenient processing of large capacity data.
In the past can not achieve the standard RAM and SRAM card file register area of continuous access,
The boundary of each area should be considered in programming Q100UDEHCPU Manual Q100UDEHCPU
The SRAM 8MB extension card is installed in the high speed universal QCPU,
Standard RAM can be used as a continuous file register,
Capacity up to 4736K words, thus simplifying the programming.
Thus, even if the memory space of the soft element is insufficient,
Can also be installed by the expansion of SRAM card, easy to extend the file register area Q100UDEHCPU Manual .
The address register is extended to 32 bits, which can be programmed to go beyond the traditional 32K word,
And to achieve the extension to the file register to all regions of the file register.
In addition, the processing speed of the index modification plays an important role in the efficient operation of structured data (array),
The speed has been improved Q100UDEHCPU Manual .
When the index is used to modify the program repeatedly (e.g. from FOR to NEXT), the scan time can be reduced.8 channel.
Input: DC4~20mA.
Output (resolution): 0~6400; 0~3200.
Conversion speed: 10ms/ channel.
18 point terminal station MITSUBISHI Q100UDEHCPU Programming Manual.
Isolation between channels.
Power supply to a two wire transmitter.
The possibility of expanding control with intelligent function MITSUBISHI Q100UDEHCPU Programming Manual.
At the same time, the channel isolation analog module realizes high isolation voltage,
Further improve the accuracy of the benchmark.
Provide support for process control using a general purpose programmable controller.
Flow meter, pressure meter, other sensors can be directly connected to analog input,
Control valve can also be directly connected to analog output MITSUBISHI Q100UDEHCPU Programming Manual.
Hardware and installation costs have been greatly reduced due to the need for an external isolation amplifier Q100UDEHCPU Common Instructions.
High insulation strength.
Can isolate electrical interference, such as current and noise, etc..
Standard analog input module.
Isolated analog input modulee Q100UDEHCPU Manual .
No external isolation amplifier required.
Without the use of inter channel isolation analog modules.
Using the inter channel isolation analog module.
Related products
MITSUBISHI
With Ethernet CPU
Q20UDEHCPU
MITSUBISHI With Ethernet CPU Q20UDEHCPU
Input / output points: 4096 points. Numer of
MITSUBISHI
With Ethernet CPU
Q26UDEHCPU
MITSUBISHI With Ethernet CPU Q26UDEHCPU
Input / output points: 4096 points. Numer of
MITSUBISHI
With Ethernet CPU
Q06UDEHCPU
MITSUBISHI With Ethernet CPU Q06UDEHCPU
Input / output points: 4096 points. Numer of
MITSUBISHI
With Ethernet CPU
Q13UDEHCPU
MITSUBISHI With Ethernet CPU Q13UDEHCPU
Input / output points: 4096 points. Numer of