LK Automation Limited
Home >> Download >> MITSUBISHI >> Manual Download >> Pt100 Input Module A1S62RD3N Manual MITSUBISHI A1S62RD3N User's Manual

Pt100 Input Module A1S62RD3N Manual MITSUBISHI A1S62RD3N User's Manual

Product model: A1S62RD3N
Name: Pt100 Input Module
Brand: MITSUBISHI
Sort: User's Manual
File language: English
File size: 2.11MB
I/O slots: 5 slots.
Outline dimension: 325*130.
CPU basic board can be plugged into 1 power modules,
1 CPU components and a maximum of 2, 3, 5, or 8 single slot size special function components and I/O components are respectively inserted and arranged.
Expansion ports are arranged on both sides of the base plate,
For connecting the expansion board for A1S62RD3N Manual .
Up to 3 extension substrates A1S62RD3N Input type: DC input, positive public end / negative public end.
Input points: 16 points.
Enter the response time: 1.5ms the following.
Rated input voltage / current: DC24V/7mA.
External connection: 3 wire.
According to the external connection mode and the external equipment input and output specifications,
Choose from a rich product lineup A1S62RD3N Manual .
Finger protection through the upper part of the terminal,
The human body will not be exposed to live parts,
Therefore, the terminal station type remote I/O module can be directly mounted to the machine tool. RS-232 1 channel, RS-422/485 1 channel.
Transfer speed: 0.3-19.2kbps.
Equipment layer / field bus CC-Link device layer is the PLC and other control devices and sensors and drive devices connected to the field network,
Network for the lowest layer of the whole network system A1S62RD3N Manual .
Using CC-Link field bus connection, the number of wiring is greatly reduced,
Improve the maintainability of the system.
And, not just the amount of data ON/OFF and other switches,
Can also be connected to the ID system, bar code reader, inverter, man-machine interface and other intelligent devices,
From the completion of a variety of data communication, the management of the terminal production information can be realized,
On the centralized management of the state of the machine movement,
Make maintenance work efficiency also greatly improved MITSUBISHI A1S62RD3N User's Manual MITSUBISHI A1S62RD3N User's Manual.
Q series PLC in the use of CC-Link function better,
And easier to use MITSUBISHI A1S62RD3N User's Manual. Capable of continuous thermocouple or platinum temperature measurement.
In addition, the temperature measurement range can be set with the use of the temperature.
The length of time required to execute the instruction, the length of the user''s program, the type of instruction, and the speed of the CPU execution are very significant,
Generally, a scanning process, the fault diagnosis time,
Communication time, input sampling and output refresh time is less,
The execution time is accounted for the vast majority of.
The response time of PLC is the interval between the time of the change of the external output signal of the PLC aand the time of the change of the external output signal which is controlled by it,
Lag time, this is the time constant of the input circuit,
The time constant of the output circuit, the arrangement of the user statement and the usse of the instruction,
The cycle scan mode of PLC and the way of PLC to refresh the I/O and so on A1S62RD3N Manual A1S62RD3N .
This phenomenon is called the I/O delay time effect.
Related products
MITSUBISHI
Analog input module
A1S64AD
MITSUBISHI Analog input module A1S64AD
4 channel analog input module. A1S64AD analog
MITSUBISHI
Temperature control module
A1S64TCRTBW-S1
MITSUBISHI Temperature control module A1S64TCRTBW-S1
Numer of channels: 4 channels Sensing method
MITSUBISHI
Analog output module
A1S62DA
MITSUBISHI Analog output module A1S62DA
2 channel analog output module. As well as an
MITSUBISHI
Temperature control module
A1S64TCTT-S1
MITSUBISHI Temperature control module A1S64TCTT-S1
Numer of channels: 4 channels. Sensing metho