5 slots; requires 1 AnS series PLC power modules;
Used to install large AnS series PLC module.
Base plate of AnS series PLC.
QA1S series PLC 5 slot main substrate.
AnS series of modules can be installed. Measurement items: leakage current (Io), resistive leakage current (Ior).
Measuring circuit number: 2 circuits MITSUBISHI Q173NCCPU Manual.
Insulation monitoring module for measuring leakage current
Q173NCCPU
Leakage current can be measured to ensure safety by monitoring the leakage current (Io), can detect the risk of electric shock.
Insulation state measurement of resistive leakage current (Ior) can be monitored continuously and continuously,
In order to continuously monitor the insulation aging status of the equipment.
Each measurement project can be carried out in the 2 phase of the alarm monitoring can be respectively on the leakage current (Io), resistive leakage current (Ior) for the 2 phase of the alarm monitoring,
No ladder diagram program MITSUBISHI Q173NCCPU Manual. Alarm monitoring is divided into 2 stages of attention alarm and danger alarm.
A module can measure two circuits of a module can be two circuits on the same line in the same system type power measurement MITSUBISHI Q173NCCPU Manual.
In addition, Works2 GX (1.90U version or higher version) can be used to easily set the parameters.
Leakage current (Io), resistive leakage current (Ior).Positioning: 3 axis, built-in counter function, open collector output type.
Control unit: pulse.
Number of location data: 1/ axis.
Maximum output pulse: 100Kpps.
Counter: 3 channels.
100Kpps.
Counter input signal: DV5~24V.
40 pin connector.
Positioning control using encoder feedback, especially suitable for conveying system and processing machinery, etc..
In the 1 single module, the 3 axis positioning function and the 3 channel counter function are integrated.
Positioning module, high-speed counter module combined as a whole,
Can effectively use the board slot and save space. GI-62.5/125 optical cable.
Double ring.
Remote I/O net (remote I/O station).Input points: 64 points.
Input voltage and current: 4mA DC24V.
Response time: 1/5/10/20/70ms.
32 point /1 a public side.
Common cathode.
40 pin connector.
Continue to go beyond, to climb the peak of Q series.
Strengthen security function.
Can be set up to 32 characters of the file password.
In addition to the English letters, numbers, but also the use of special characters,
To further enhance the security of the password.
In addition, only pre registered devices are allowed to access CPU,
To intercept unauthorized access to unauthorized users.
Therefore, it is important to prevent the outflow of important program assets and protect intellectual property rights.
Easy connection programming tool via ethernet.
Programming tools (Works2 GX, Developer GX) and CPU direct connection (1 to 1),
No need to carry out the IP address settings. And there is no need to select the cable, the straight line and the cross line can be used.
Therefore, this connection method and the use of USB, can easily communicate with the CPU,
Even the operators are not familiar with the network settings can easily establish a connection.
A variety of modules with excellent performance,
Meet the needs of various control from analog to location.
Q series module products include a variety of types of I/O, analog and positioning function module Q173NCCPU Strctured Programming Manual.
Can fully meet the switch, sensor, such as the input and output, temperature, weight, flow and motor, drive control,
As well as the requirements of high-precision control of thhe positioning of the industry, the control needs of various fields Q173NCCPU Strctured Programming Manual.
Can also be used in combination with the CPU module to achieve appropriate control.