Output: 2 channels.
Input (resolution): 0~4000; -4000~4000; 0~12000; -12000~12000; -16000~16000.
Output: DC-10~10V; DC0~20mA.
Conversion speed: 80 s/1 channel.
18 point terminal station.
Transformer isolation between power supply and output.
High insulation strength.
Can isolate electrical interference, such as current and noise, etc MITSUBISHI Q25PRHCPU Programming Manual. .
Standard analog input module
Q25PRHCPU
Isolated analog input module.
No external isolation amplifier required.
Without the use of inter channel isolation analog modules.
Using the inter channel isolation analog module.
The possibility of expanding control with intelligent function.
Providing a variety of analog modules, is the ideal choice for process control applications MITSUBISHI Q25PRHCPU Programming Manual.
Can also meet the needs of high speed, high precision control.
Most suitable analog modules for high speed conversion control.
Can provide a variety of analog and digital analog conversion module products.
These modules have a variety of functions, in the connection of equipment, to achieve the greatest flexibility.
Can meet the inverter control, such as high-speed conversion needs.
A variety of modules with excellent performance,
Meet the needs of various control from analog to location MITSUBISHI Q25PRHCPU Programming Manual.
Q series module products include a variety of types of I/O, analog and positioning function module.
Can fully meet the switch, sensor, such as the input and output, temperature, weight, flow and motor, drive control,
As well as the requirements of high-precision control of the positioning of the industry, the control needs of various fields.
Can also be used in combination with the CPU module to achieve appropriate control. Input points: 32 points.
Input voltage and current: 1.2mA DC5/12V (DC5V) /3.3mA (DC12V).
Response time: 1/5/10/20/70ms.
32 point /1 a public side.
Positive / negative common.
40 pin connector.
Easy connection programming tool via ethernet.
Programming tools (Works2 GX, Developer GX) and CPU direct connection (1 to 1),
No need to carry out the IP address settings. And there is no need to select the cable, the straight line and the cross line can be used.
Therefore, this connection method and the use of USB, can easily communicate with the CPU,
Even the operators are not familiar with the network settings can easily establish a connection.
A variety of modules with excellent performance,
Meet the needs of various control from analog to location.
Q series module products include a variety of types of I/O, analog and positioning function module.
Can fully meet the switch, sensor, such as the input and output, temperature, weight, flow and motor, drive control,
As well as the requirements of high-precision control of the positioning of the industry, the control needs of various fields.
Can also be used in combination with the CPU module to achieve appropriate control.
Continue to go beyond, to climb the peak of Q series.
Strengthen security function.
Can be set up to 32 characters of the file passwoord Q25PRHCPU Manual .
In addition to the English letters, numbers, but also the use of special characters,
To further enhance the security of the password.
In addition, only pre registered devices are allowed to access CPU,
To intercept unauthorizeed access to unauthorized users Q25PRHCPU Manual .
Therefore, it is important to prevent the outflow of important program assets and protect intellectual property rights.