4 channel.
Input: DCO~20mA DC-10~10V.
Output (resolution): 0~4000; -4000~4000; 0~12000; -12000~12000; 0~16000; -16000~16000;
Conversion speed of 80 s/1 channel.
18 point terminal station.
The possibility of expanding control with intelligent function.
Providing a variety of analog modules, is the ideal choice for process control applications MITSUBISHI Interface Module User's Manual.
Can also meet the needs of high speed, high precision control
QJ71FL71-B2-F01
Most suitable analog modules for high speed conversion control.
Can provide a variety of analog and digital analog conversion module products.
These modules have a variety of functions, in the connection of equipment, to achieve the greatest flexibility.
Can meet the inverter control, such as high-speed conversion needs MITSUBISHI Interface Module User's Manual.
A variety of modules with excellent performance,
Meet the needs of various control from analog to location.
Q series module products include a variety of types of I/O, analog and positioning function module.
Can fully meet the switch, sensor, such as the input and output, temperature, weight, flow and motor, drive control,
As well as the requirements of high-precision control of the positioning of the industry, the control needs of various fields MITSUBISHI Interface Module User's Manual.
Can also be used in combination with the CPU module to achieve appropriate control.3 slots; requires 1 AnS series PLC power modules;
Used to install large AnS series PLC module QJ71FL71-B2-F01 User's Manual.
Base plate of AnS series PLC.
QA1S series PLC 3 slot main substrate.
AnS series of modules can be installed QJ71FL71-B2-F01 User's Manual. Input: 4 channels.
Thermocouple (K, J, T, B, S, E, R, N, U, L, PLlI, W5Re/W26Re,,).
No heater disconnection detection function.
Sampling period: 0.5s/4 channel.
18 point terminal station.
Peak current suppression.
Can prevent the simultaneous opening of the output to control the peak current, which is helpful for saving energy and reducing the operation cost QJ71FL71-B2-F01 User's Manual.
Heating function at the same time.
The multiple loop can reach the set value at the same time to carry out the uniform temperature control,
Helps to prevent no-load and effective energy saving and reduce operating costs.
Automatic adjustment function.
The PID constant can be adjusted automatically in the control process.
Automatic adjustment of cost (time, material and electrical energy) can be reduced.
Can be flexible in various settings, to achieve the best temperature control of the temperature control module.
Equipment for high temperature control stability of extrusion molding machine,
The temperature regullating module has the function of preventing overheating and preventing over cooling QJ71FL71-B2-F01 Manual.
According to the control object device, select the standard control (heating or cooling) or the heating and cooling contrrol (heating and cooling) mode MITSUBISHI Interface Module User's Manual.
In addition, the mixed control mode (combined with the standard control and heating - cooling control) can be selected.