Max input / output points: 20 points.
Power supply voltage: 24VDC.
Input points: 12 points.
Output points: 8 points.
Output type: relay.
Power consumption (W): 7.
Weight (kg):0.3.
Size (WxHxD) mm:75x90x49.
Host has 10 points (6I/4O), 14 points (8I/6O), 20 points (12I/8O), 30 points (16I/14O) of 4 types FR-A540-30K-CH TECHNICAL MANUAL.
This type of PLC is mainly used in all of the digital input, digital output control point of the device
FR-A540-30K-CH
Can be directly connected to the 220V city power, built-in 8K step EEPROM memory, no battery, easy to maintain.
The series transistor output (MT) of the PLC, can be output 2 100KHz pulse, direct drive servo or stepper motor.
The series PLC can not be brought with the expansion module, but can be installed by the BD board to extend a small amount of I/O FR-A540-30K-CH TECHNICAL MANUAL.
The series 1N through the installation of BD series PLC board, can achieve RS232, RS485, RS422 communication.
All equipment is digital input and output point.
The total I/O points are not more than 30 points, and the input points are less than 16, the output points are less than 14.
Its MT series of PLC can drive 2 way servo or stepper, commonly used in the control system for a simple manipulator FR-A540-30K-CH TECHNICAL MANUAL. MITSUBISHI inverter series: FR-F820.
Voltage level: three phase 200V.
Power: 55kw.
SLD converter rated current: 316A.
Structure and function: Standard model.
Type: CA MITSUBISHI FR-A540-30K-CH Manual.
Substrate coating: have.
PID target value can be set directly from the operator panel. Flexible change settings.
In the 1 inverter, through the PID control of parallel connection pump (up to 4 units) can adjust the amount of water and so on MITSUBISHI FR-A540-30K-CH Manual.
1 pumps driven by parallel connection of the pump machine, in addition to the pump for power frequency drive.
The number of power frequency driven pump, according to the automatic adjustment of water MITSUBISHI FR-A540-30K-CH Manual.
The liquid crystal panel options (FR-LU08) can be converted to a more intuitive display unit% units.
Through the use of wind, temperature and other familiar units can be simple to maintain and adjust the display. Output points: 32 points
Output form: Transistor (drain type) FR-A540-30K-CH .
Connection status: connector.
In order to extend the input output of the device.
Also has a built-in power supply products.
The maximum number of points for the input and output is 256.
Expansion modulee: up to 16 units (in addition to the power expansion module)
The total number of CC-Link, AnyWireASLINK, and Bitty series of remote I/O is 512 points FR-A540-30K-CH TECHNICAL MANUAL.