The main body: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: silver.
Control output: relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater with broken wire, SSR fault, heater over current detection function /ES1B power supply: single phase heater with detection function E5AN-Q3H01T-FLK-N MANUAL
E5AN-Q3H01T-FLK-N
Event input points: -.
Transfer output: -.
Communication: RS-485.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventive maintenance function is increased,
Further performance improvement.
E5CN-U (insert type) add analog input and current output type E5AN-Q3H01T-FLK-N MANUAL.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV.
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay. Size: 48 * 48mm, terminal type.
Category: control output 1 point type (power supply AC100 ~ 240V) E5AN-Q3H01T-FLK-N MANUAL.
Shell color: black.
Control output: current output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: -.
Event input points: -.
Transfer output: output (using control output) OMRON E5AN-Q3H01T-FLK-N User's Manual.
Communication: -.
New program type.
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved OMRON E5AN-Q3H01T-FLK-N User's Manual.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C (to achieve a small size of 48 x 48mm).
High speed sampling period 60ms.
Full of all models (capable of thermocouple /Pt/ analog input switching),
1 machines to support a variety of sensors OMRON E5AN-Q3H01T-FLK-N User's Manual.
Add PV/SV state display function, to see the state of the tthermostat
(automatic / manual, RUN/RESET, alarm),
Interactive display PV/SV E5AN-Q3H01T-FLK-N Communications Functions.
By supporting software (Ver.4.3 CX-Thermo),
In simple arithmetic functions (AND/OR logic and delay).
Setting the program settings that can performm flexible contact output E5AN-Q3H01T-FLK-N MANUAL.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller.