Control output: relay output.
Auxiliary output: 2 points.
Heating wire breakage, SSR fault detection function: single phase heater detection function.
Event input: -.
Communication: RS-485.
Terminal shape: main unit (no terminal unit).
Power supply voltage: AC/DC24V.
DIN rail operation, high performance E5 / C series of the maintenance of the most suitable system connected with a touch screen /PLC and thermostat installation type E5AR-C43B-FLK INSTRUCTION Manual
E5AR-C43B-FLK
DIN 85mm * 22.5MM width depth guide installation type, housed in the control cabinet of the thin slender body.
The terminal platform can be easily replaced, and the maintenance performance is improved.
Through the 50ms high speed sampling, suitable for the use of high speed heating E5AR-C43B-FLK INSTRUCTION Manual.
Easy to connect with PLC through no program communication.
The use of communication adapter cable (sold separately) connected to the computer, without power supply connection
Set up。 It can be easily set by CX-Thermo (sold separately).
With auxiliary output (maximum 2 points), event input (maximum 1 points), the basic function is complete.
The confirmation of a simple, eye-catching white PV display when starting or abnormal in the cabinet
(PV high 8 E5AR-C43B-FLK INSTRUCTION Manual. 5mm). Case color: Black.
Control output: Current output.
Control mode *1: Standard or heating/cooling.
No. of auxiliary outputs: 1 OMRON E5AR-C43B-FLK Manual.
Detection of heater burnout, SSR failure, and heater overcurrent: --.
No. of event inputs: --.
Transfer output *2: Transfer output using control output OMRON E5AR-C43B-FLK Manual.
Communi cations: RS-485.
Previous model: Thermocouple input, --;
Resistance thermometer input, --.
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy OMRON E5AR-C43B-FLK Manual.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0.5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Temperature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV E5AR-C43B-FLK .
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
Switch the PV display between three colorrs E5AR-C43B-FLK INSTRUCTION Manual.
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs.