Ontology: program type.
Size: 48 x 96mm.
Type: basic type (1 input).
Control mode: standard control, heating and cooling control.
Output (control / transfer) points: 2 points (current + current).
Output (SUB) points: 4 points.
Event entry point: 2.
Serial communication: -.
New high speed, high precision digital regulator (Cheng Xuxing)!
Can be set up to 32 kinds of procedures E5EN-HPRR203BFD-FLK INSTRUCTION Manual
E5EN-HPRR203BFD-FLK
1 units can be coordinated to run up to 4 channels.
High speed acquisition of 50ms.
With CX-Thermo on the computer easily set. Terminal type: Exposed-lead Models.
Protective tubing diameter D (mm): 1 dia.
Protective tubing length L: 15cm.
Lead wire type: Heat resistive.
Lead wire length M : 4m.
A Wide Variety of High-precision E5EN-HPRR203BFD-FLK INSTRUCTION Manual.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal E5EN-HPRR203BFD-FLK INSTRUCTION Manual. The main body: terminal type, temperature input type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: relay output and long life.
Control mode: standard or heating cooling OMRON E5EN-HPRR203BFD-FLK Manual.
Auxiliary output points: 2 points.
Heater with broken wire, SSR fault, heater over current detection function /ES1B power supply: single phase heater with detection function OMRON E5EN-HPRR203BFD-FLK Manual.
Event entry point: 2.
Transfer output: -.
Communication: -.
48mm general thermostat has been upgraded & function / performance upgrade.
Indicates that the accuracy is increased and the preventive maintenance function is increased,
Further performance improvement OMRON E5EN-HPRR203BFD-FLK Manual.
E5CN-U (insert type) add analog input and current output type.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV E5EN-HPRR203BFD-FLK .
Increase the number of control output ON/OFF counting function, can prevent the maintenance of temperature controller internal relay. E32-S15-1 fiber unit uses OMRON'''s original polarized light multilayer technology (FAO)
Can not be affected by the color of the workpiece, the subtle luster
To carry out a stable test