Receptacle box: G 1/2 Conduit.
Indicator: With neon lamp indicator (AC).
Actuator: Roller lever *1, High-sensitivity.
Approved standards: UL, CSA.
The Limit Switch with Better Seal,
Shock Resistance, and Strength.
A double seal on the head, a complete gasket cover, and,
other features ensure a better seal (meets UL NEMA 3, 4, 4X, 6P, 12, 13) D4SL-N3PDG-D4N INSTRUCTION sheet.
Wide standard operating temperature range:
-40°C to +100°C (standard type)
D4SL-N3PDG-D4N
Models with fluoro-rubber available for greater resistance to chemicals.
Block mounting method also reduces downtime for maintenance.
DPDT, double-break models available for complex operations.
Approved by UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved model D4SL-N3PDG-D4N INSTRUCTION sheet. ) Actuator type: Roller lever.
Compact Vertical Models Sized for Asian.
Standards.
Compact new design approximately 1/3 the size of OMRON,
vertical Limit Switches.
Structure enables the terminal section to be fully opened for,
easy wiring.
RoHS complaint.
Degree of protection: IP65. Ratings: Standard load; 4 A at 30 VDC.
Cable: VCTF oil-resistant cable *1 D4SL-N3PDG-D4N INSTRUCTION sheet.
Actuator: Sealed roller plunger.
Cable length : 3 m.
Compact Limit Switch That''s Also.
Thin and Highly Sealed.
Approved by EN, UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved models OMRON D4SL-N3PDG-D4N Manual. )
Sealing characteristics that meet IEC IP67 degree of protection.
Triple-sealed construction:
Plunger section sealed via nitrile rubber packing seal and,
diaphragm; switch section sealed via nitrile rubber cap;
cable entrance sealed via encapsulating material OMRON D4SL-N3PDG-D4N Manual.
Cable lengths of 3 and 5 m available on standard models.
Models also available with UL and CSA-certified cables.
Multiple mounting possible with Switches with Plungers OMRON D4SL-N3PDG-D4N Manual.
Models with red LED indicators added to series for easy,
confirmation of operation.
(Set by default to light for non-operation.)
VCTF oil-resistant cables with CE marking.
(Applicable only to standard models.)Release Key Type: Special (resin).
Wiring method: Connector.
Solenoid voltage/Indicator: 24VDC (Orange).
Lock and release type: Mechanical lock Solenoid release.
Contact configuration (door open/closed detection switch,
and lock monitor switch contacts): 6-contact Model,
Insert the built-in switch (N, P, Q or R) into the blank @.
Conduit size (See Note.): G1/2.
World''s smallest Class 6-contact Guard Lock.
Safety-door Switch.
.
Wiring time is reduced with two types of wiring.
methods capable of one-touch attachment and removal.
A wide variety of built-in switches can be used for various devices.
(4-, 5-, and 6-contact models are available).
Key holding force of 1,300 N.
It is possible to change the key insertion point.
wiithout detaching the head D4SL-N3PDG-D4N .
Drive solenoids directly from the Controller.
.
Lockout Key to prevent workers from becoming.
trapped inside the hazardous area.
The vertical D4SL Guard Lock Safety-door Switch,
can be easily mounted on 40 × 40 mm aluminum frames D4SL-N3PDG-D4N INSTRUCTION sheet.
The plastic material makes the Slide Key suitable,
for lightweight doors.