Control output 1: Voltage output.
Auxiliary output: Two.
Communications: --.
Heater burnout: --.
Event inputs: --.
Power supply voltage: 24 VAC/VDC.
Large White PV Display That’s Easier to Read.
Easy to Use, from Model Selection to,
Setup and Operation.
A Complete Range of I/O Capacities,
Functions, and Performance E3T-FL22R INSTRUCTION sheet.
Handles More Applications.
The white PV display with a height of 15
E3T-FL22R2 mm improves visibility.
High-speed sampling at 50 ms.
Short body with depth of only 60 mm.
Easy connections to a PLC with programless communications.
Use component communications to link Temperature.
Controllers to each other. Protective tubing length (mm): M6 screw.
Lead wire length: 2 m.
A Wide Variety of High-precision E3T-FL22R INSTRUCTION sheet.
Temperature Sensors.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal E3T-FL22R INSTRUCTION sheet. Case color: Black.
Control output: Voltage output (for driving SSR).
Control mode *1: Standard.
No. of auxiliary outputs: --.
Detection of heater burnout, SSR failure, and heater overcurrent: -- OMRON E3T-FL22R Manual.
No. of event inputs: --.
Transfer output *2: --.
Communi cations: --.
Previous model: Thermocouple input, E5GN-QTC;
Resistance thermometer input, E5GN-QP OMRON E3T-FL22R Manual.
New 48 x 24-mm Basic Temperature,
Controller with Enhanced Functions and,
Performance. Improved Indication Accuracy,
and Preventive Maintenance Function.
Indication Accuracy.
Thermocouple input: ±0.3% of PV (previous models: ±0.5%),
Pt input: ±0.2% of PV (previous models: ±0 OMRON E3T-FL22R Manual. 5%),
Analog input: ±0.2% FS (previous models: ±0.5%),
Models are available with screw terminal blocks or screwless,
clamp terminal blocks.
A PV/SV-status display function can be set to automatically alternate,
between displaying the status of the Temperaature Controller (auto/
manual, RUN/STOP, and alarms) and the PV or SV E3T-FL22R .
Preventive maintenance for relays in the Temperature,
Controller using a Control Output ON/OFF Counter.
Switch the PV display between three colorrs E3T-FL22R INSTRUCTION sheet.
Compatible with Support Software (CX-Thermo version 4.2 or higher).
Eleven-segment displays.
Models are available with one or two alarm outputs.