Size: 48 * 48mm, terminal type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: relay output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: single phase heater detection function E2E-C04S12-MC-C1 Manual.
Event entry point: 2.
Transfer output: -.
Communication: -.
New program type
E2E-C04S12-MC-C1
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C (to achieve a small size of 48 x 48mm).
High speed sampling period 60ms E2E-C04S12-MC-C1 Manual.
Full of all models (capable of thermocouple /Pt/ analog input switching),
1 machines to support a variety of sensors.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm),
Interactive display PV/SV.
By supporting software (Ver.4.3 CX-Thermo),
In simple arithmetic functions (AND/OR logic and delay).
Setting the program settings that can perform flexible contact output E2E-C04S12-MC-C1 Manual.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller. Connecting method: Wire-saving Connector.
Models: NPN output, E3X-HD6.
Easy and optimum settings for anyone OMRON E2E-C04S12-MC-C1 INSTRUCTION sheet.
Smart Fiber Amplifier Unit with Long-term Stable Detection.
Equipped with Smart Tuning, which automatically configures the,
settings to their optimum values with the press of a single button OMRON E2E-C04S12-MC-C1 INSTRUCTION sheet.
Highly usable design enables anyone to configure the settings easily.
Detects dirt, vibrations, and LED deterioration, and automatically,
compensates the incident level and the light intensity.
Unparalleled best-in-class power provides stable detections for low,
reflective workpieces and large workpieces (equipped with GIGA RAY II) OMRON E2E-C04S12-MC-C1 INSTRUCTION sheet.
Classification: General purpose Models.
Description: Sheathed thermocouple.
Temperature range (See note 3.): 0°C to 900°C.
Element type: K (CA) J (IC).
Conductor type: Non grounded type.
Class: 2 (0.75).
Protective tubing material: ASTM316L.
Terminal type: Enclosed terminals.
Page: 13.
A Wide Variety of High-precision.
Temperature SSensors E2E-C04S12-MC-C1 .
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Teemperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal E2E-C04S12-MC-C1 Manual.