LK Automation Limited
Home >> Download >> OMRON >> Manual Download >> pull-reset safety limit switch D4N-5D31R Manual OMRON D4N-5D31R INSTRUCTION sheet

pull-reset safety limit switch D4N-5D31R Manual OMRON D4N-5D31R INSTRUCTION sheet

Product model: D4N-5D31R
Name: pull-reset safety limit switch
Brand: OMRON
Sort: INSTRUCTION sheet
File language: English
File size: 0.54MB
Specifications: I/O; PNP (input: - common,
output: + common); 8 inputs/8 outputs.
I/O connections: Sensor connector.
Rated internal circuit power supply voltage:
Supplied from the communications connector.
Rated I/O power supply voltage:
Supplied from external source for outputs.
Includes Sensor Connector That Conforms to,
Industry Standards And Can Be Used to Connect D4N-5D31R Manual.
Sensors with Pre-wired Cables without Using,
Special Tools D4N-5D31R
Equipped with the standard Smart Slave,
functions that provide powerful.
preventative maintenance and,
troubleshooting capabilities.
Digital I/O Terminal compatible with,
industry-standard sensor connectors.
Connect sensors easily without special tools D4N-5D31R Manual.
Reduce time required for wiring.
Load short-circuit detection. Release key type: Special release key.
Indicator: Green.
Lock and release types: Solenoid lock Mechanical release.
Contact configuration(door open/closed detection switch,
and lock monitor switch contacts): 2NC/1NO+3NC.
Conduit opening: M20.
Holding Force of 3,000 N.
Two safety circuits and two monitor contacts provide an,
array of monitoring patterns D4N-5D31R Manual.
Standard gold-clad contacts enable use with ordinary loads,
and microloads.
Models with trapped keys prevent workers from being locked,
in hazardous work areas.
Models with rear release buttons allow people to unlock the,
Switch and escape if they are locked into hazardous areas OMRON D4N-5D31R INSTRUCTION sheet.
IP67 degree of protection. Actuator: Adjustable roller lever, form lock (metal lever, resin roller) OMRON D4N-5D31R INSTRUCTION sheet.
Conduit size: 1-conduit; Pg13.5.
Built-in switch mechanism: 2NC (Slow-action).
A Series of Pull-reset Models Now.
Available.
Lineup includes three contact models with 2NC/1NO and 3NC,
contact forms in addition to the previous contact forms 1NC/1NO and 2NC.
M12-connector models are available, saving on labor and,
simplifying replacement OMRON D4N-5D31R INSTRUCTION sheet.
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115, EN81-1 and EN81-2.
Certified standards: UL, EN (TÜV), and CCC. Ratings: Standard load; 0.1 A at 125 VAC, 0.1 A at 30 VDC.
Cable: VCTF oil-resistant cable *1.
Actuator: Roller lever.
Cable length : 3 m.
Compact Limit Switch That''s Also.
Thin and Highly Sealed.
Approved by EN, UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved models.)
Sealing characteristics that meet IEC IP67 degree of protection.
Triple-sealed construction:
Plunger section sealed via nitrile rubber packing seal and,
diaphragm; switch section sealed via nitrile rubber cap;
cable entrance sealed via encapsulating material.
Caable lengths of 3 and 5 m available on standard models D4N-5D31R .
Models also available with UL and CSA-certified cables.
Multiple mounting possible with Switches with Plungers.
Models with red LED indicators added to series for easy,
connfirmation of operation D4N-5D31R Manual.
(Set by default to light for non-operation.)
VCTF oil-resistant cables with CE marking.
(Applicable only to standard models.)
Related products
OMRON
Safety Limit Switch
D4N-1A62
OMRON Safety Limit Switch D4N-1A62
Actuator: One-way roller arm lever horizonta
OMRON
Safety Limit Switch
D4N-1F25
OMRON Safety Limit Switch D4N-1F25
Actuator: Roller lever metal lever, metal ro
OMRON
Safety Limit Switch
D4N-4D32
OMRON Safety Limit Switch D4N-4D32
Actuator: Roller plunger. Conduit size: 1-co
OMRON
Safety Limit Switch
D4N-8D2H
OMRON Safety Limit Switch D4N-8D2H
Actuator: Adjustale roller lever, form lock