LK Automation Limited
Home >> Download >> OMRON >> Manual Download >> safety limit switch D4N-2D31 INSTRUCTION sheet OMRON D4N-2D31 Manual

safety limit switch D4N-2D31 INSTRUCTION sheet OMRON D4N-2D31 Manual

Product model: D4N-2D31
Name: safety limit switch
Brand: OMRON
Sort: INSTRUCTION sheet
File language: English
File size: 0.61MB
Receptacle box: G 1/2 Conduit.
Indicator: Without indicator.
Actuator: Top plunger, Standard.
Approved standards: UL, CSA.
The Limit Switch with Better Seal,
Shock Resistance, and Strength.
A double seal on the head, a complete gasket cover, and,
other features ensure a better seal (meets UL NEMA 3, 4, 4X, 6P, 12, 13) D4N-2D31 INSTRUCTION sheet.
Wide standard operating temperature range:
-40°C to +100°C (standard type) D4N-2D31
Models with fluoro-rubber available for greater resistance to chemicals.
Block mounting method also reduces downtime for maintenance.
DPDT, double-break models available for complex operations.
Approved by UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved model D4N-2D31 INSTRUCTION sheet. ) Actuator: Roller plunger.
Conduit size: 2-conduit; G1/2.
Built-in switch mechanism: 1NC/1NO (Slow-action).
Popular Safety Limit Switches.
Providing a Full Lineup Conforming to,
International Standards.
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contact forms.
(Slow-action models with MBB contacts are available.)
M12-connector models are also available, saving on labor and,
simplifying replacement D4N-2D31 INSTRUCTION sheet.
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only) OMRON D4N-2D31 Manual.
Certified standards: UL, EN (TÜV), and CCC. Actuator: Pin plunger.
Type: M16.
Operation Indicator: Provided.
Repeat accuracy: 3 µm max OMRON D4N-2D31 Manual.
Operating force OF max: 2.45 N.
Cable lead outlet: Lead outlet, Pre-wired; Length, 1 m.
Degree of protection: IP67.
High-precision Switch for Detecting Micron-unit,
Displacement.
Ideal for detecting and measuring wear of cutting,
tools or for original point of work.
Ceramic plungers on M5, M8, and slim models for,
superior abrasion resistance and resistance to,
temperature changes OMRON D4N-2D31 Manual.
Direct input possible to microprocessors and,
programmable controllers.
A version with screw-type cable connector available,
for easy installation and maintenance. Actuator: One-way roller arm lever (horizontal).
Conduit size: 1-conduit; Pg13.5.
Built-in switch mechanism: 2NC/1NO (Slow-action).
A Series of Pull-reset Models Now.
Available.
Lineup includes three contact models with 2NC/1NO and 3NC,
contact forms in addition to the previous contact forms 1NC/1NO and 2NC D4N-2D31 .
M12-connector models are available, saving on labor and,
simplifying replacement.
Standardized gold-clad contacts provide high contact reliability D4N-2D31 INSTRUCTION sheet.
Can be used with both standard loads and microloads.
Conforms to EN115, EN81-1 and EN81-2.
Certified standards: UL, EN (TÜV), and CCC.
Related products
OMRON
Safety Limit Switch
D4N-4D31
OMRON Safety Limit Switch D4N-4D31
Actuator: Plunger. Conduit size: 1-conduit
OMRON
Pull-reset Safety Limit Switch
D4N-9A2GR
OMRON Pull-reset Safety Limit Switch D4N-9A2GR
Actuator: Adjustale roller lever, form lock
OMRON
Safety Limit Switch
D4N-2A31
OMRON Safety Limit Switch D4N-2A31
Actuator: Plunger. Conduit size: 1-conduit
OMRON
Safety Limit Switch
D4N-2D26
OMRON Safety Limit Switch D4N-2D26
Actuator: Roller lever metal lever, earing