Product model: D4N-8C62
Name: safety limit switch
Brand: OMRON
Sort: INSTRUCTION sheet
File language: English
File size: 0.61MB
Release key type: Special release key.
Indicator: Orange.
Lock and release types: Solenoid lock Mechanical release.
Contact configuration(door open/closed detection switch,
and lock monitor switch contacts): 3NC+2NC/1NO.
Conduit opening: M20.
Holding Force of 3,000 N.
Two safety circuits and two monitor contacts provide an,
array of monitoring patterns D4N-8C62 INSTRUCTION sheet.
Standard gold-clad contacts enable use with ordinary loads,
and microloads D4N-8C62
Models with trapped keys prevent workers from being locked,
in hazardous work areas.
Models with rear release buttons allow people to unlock the,
Switch and escape if they are locked into hazardous areas.
IP67 degree of protection. Actuator: One-way roller arm lever (vertical) D4N-8C62 INSTRUCTION sheet.
Conduit size: 1-conduit; G1/2.
Built-in switch mechanism: 1NC/1NO MBB(Slow-action).
Popular Safety Limit Switches.
Providing a Full Lineup Conforming to,
International Standards.
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contact forms.
(Slow-action models with MBB contacts are available.)
M12-connector models are also available, saving on labor and,
simplifying replacement D4N-8C62 INSTRUCTION sheet.
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only) OMRON D4N-8C62 Manual.
Certified standards: UL, EN (TÜV), and CCC. Actuator: Roller plunger.
Conduit size: 2-conduit; G1/2.
Built-in switch mechanism: 2NC (Slow-action) OMRON D4N-8C62 Manual.
Popular Safety Limit Switches.
Providing a Full Lineup Conforming to,
International Standards.
Lineup includes models with 1NC/1NO, 2NC, 2NC/1NO and,
3NC contact forms.
(Slow-action models with MBB contacts are available.)
M12-connector models are also available, saving on labor and,
simplifying replacement OMRON D4N-8C62 Manual.
Standardized gold-clad contacts provide high contact reliability.
Can be used with both standard loads and microloads.
Conforms to EN115-1, EN81-1, and EN81-2 (slow-action models only).
Certified standards: UL, EN (TÜV), and CCC. Ratings: Standard load; 5 A at 250 VAC, 4 A at 30 VDC.
Cable: VCTF cable *2.
Actuator: Crossroller plunger.
Cable length : 5 m.
Compact Limit Switch That''s Also.
Thin and Highly Sealed.
Approved by EN, UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved models.)
Sealing characteristics that meet IEC IP67 degree of protection.
Triple-sealed construction:
Plunger section sealed via nitrile rubber packing seal and,
diaphragm; switch section sealed via nitrile rubber cap;
cable entrance sealed via encapsulating material.
Cable lengthhs of 3 and 5 m available on standard models D4N-8C62 .
Models also available with UL and CSA-certified cables.
Multiple mounting possible with Switches with Plungers.
Models with red LED indicators added to series for easy,
connfirmation of operation D4N-8C62 INSTRUCTION sheet.
(Set by default to light for non-operation.)
VCTF oil-resistant cables with CE marking.
(Applicable only to standard models.)
Related products
OMRON
Safety Limit Switch
D4N-8122
OMRON Safety Limit Switch D4N-8122
Actuator: Roller lever metal lever, resin ro
OMRON
Safety Limit Switch
D4N-4E25
OMRON Safety Limit Switch D4N-4E25
Actuator: Roller lever metal lever, metal ro
OMRON
Safety Limit Switch
D4N-4C26
OMRON Safety Limit Switch D4N-4C26
Actuator: Roller lever metal lever, earing
OMRON
Safety Limit Switch
D4N-1C32
OMRON Safety Limit Switch D4N-1C32
Actuator: Roller plunger. Conduit size: 1-co