LK Automation Limited
Home >> Download >> OMRON >> Manual Download >> sensor head E2C-ED02 Manual OMRON E2C-ED02 INSTRUCTION sheet

sensor head E2C-ED02 Manual OMRON E2C-ED02 INSTRUCTION sheet

Product model: E2C-ED02
Name: sensor head
Brand: OMRON
Sort: INSTRUCTION sheet
File language: English
File size: 8.42MB
Size: 48 * 48mm, terminal type.
Category: control output 1 point type (power supply AC100 ~ 240V).
Shell color: black.
Control output: linear voltage output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
Heater break, SSR fault detection function: -.
Event entry point: 2 E2C-ED02 Manual.
Transfer output: output (special terminal).
Communication: -.
New program type E2C-ED02
A new type of liquid crystal with high performance cost ratio is adopted in the 256 paragraph,
Visual angle, contrast can be improved.
Can be set up to 8 procedures (mode) x 32 (step) procedure.
High resolution 5 bit display / can display 0.01 degrees C (to achieve a small size of 48 x 48mm).
High speed sampling period 60ms E2C-ED02 Manual.
Full of all models (capable of thermocouple /Pt/ analog input switching),
1 machines to support a variety of sensors.
Add PV/SV state display function, to see the state of the thermostat
(automatic / manual, RUN/RESET, alarm),
Interactive display PV/SV.
By supporting software (Ver.4.3 CX-Thermo),
In simple arithmetic functions (AND/OR logic and delay).
Setting the program settings that can perform flexible contact output E2C-ED02 Manual.
The control output ON/OFF times counting function can predict the fault of the internal relay of the temperature controller. Name: Temperature Controller (See note 1.).
Power supply: 24 VDC.
No. of control points: 2.
Control output: Transistor output OMRON E2C-ED02 INSTRUCTION sheet.
Auxiliary output: Transistor output: 2 pts (sourcing).
Functions: Heater burnout alarm (See note 3.), Heating or heat/cool,
control is selectable (See note 4 OMRON E2C-ED02 INSTRUCTION sheet. )Event input: 1 point per Unit.
Communications functions: RS-485.
Input type (See note 5.): Thermocouple.
New DIN Track Mounting Temperature.
Controller.
Two channels of temperature control available despite width of,
only 22.5 mm.
The Temperature Controller itself can be replaced without,
changing terminal wiring OMRON E2C-ED02 INSTRUCTION sheet E2C-ED02 .
Use in combination with a compact Setting Display Unit to,
reduce communications programming requirements.
Front-panel LED indicators for easy operation monitoring.
Power supply and communicatiions wiring not required between,
Units when mounted side-by-side E2C-ED02 Manual.
CompoWay/F communications protocol supported.
UL, CSA, and CE Marking compliance.