Product model: G3J-S405BL
Name: solid-state contactor
Brand: OMRON
Sort: INSTRUCTION MANUAL
File language: English
File size: 13.57MB
Input capacity: 16 points.
Internal I/O common: NPN.
ON voltage: 15 VDC min. (between each in,
put terminal and the V terminal).
OFF voltage: 5 VDC max. (between each in,
put terminal and the V terminal).
OFF current: 1.0 mA max.
Input current: 6.0 mA max./input (at 24-VDC),
3.0 mA min./input (at 17-VDC) G3J-S405BL INSTRUCTION MANUAL.
ON delay: 0.1 ms max.
OFF delay: 0.2 ms max.
Input filter value: Without filter, 0 G3J-S405BL5 ms,
1 ms, 2 ms, 4 ms, 8 ms, 16 ms, 32 ms.
(Default setting: 1ms)
Number of circuits per common: 16 points/common.
Input indicators: LED display (yellow).
Isolation method: No isolation.
I/O power supply method: Supplied from unit power supply.
Input device supply current: 50 mA/point.
Unit power supply current consumption: 150 mA max G3J-S405BL INSTRUCTION MANUAL.
(for 20.4 to 26.4-VDC power supply voltage)
e-CON Connector insertion durability: 50 times.
Weight: 140 g max.
Expansion functions: No.
Short-circuit protection function: Available.
(Operates at 50 mA/point min.)
Easy wiring using industry standard,
e-CON connectors.
Special wiring tool is not necessary.
Digital I/O terminal with industry,
standard e-CON connectors G3J-S405BL INSTRUCTION MANUAL.
A common terminal is provided for,
each connector.
The I/O terminal and the sensors can,
be connected directly.
Input response time can be switched for,
high-speed processing OMRON G3J-S405BL Manual.
Selectable node address setting methods:
setting with rotary,
switch and with tool software.
When setting the nodes with rotary switch,
setting is easy and node identification,
becomes possible for maintenance OMRON G3J-S405BL Manual. Alarm output: 1 output (Heater Burnout Detection,
SSR Short-circuit Failure Detection, Common).
Applicable load (See note.): 2 to 35 A, 200 to 480 VAC.
A New-concept SSR with Built-in.
Current Transformer.
Heater Burnout and SSR Short OMRON G3J-S405BL Manual.
circuit Failure Detection.
Built-in Current Transformer (CT) helps reduce wiring steps.
Detects the burnout of any one of a group of heaters.
Detects the burnout of 3-phase heaterss G3J-S405BL .
Detects SSR short-circuit failures.
Error detection level can be easily set with a switch.
Mounts to a DIN track or with screws.
Three types of input terminals available: M3 terminals,
screwless clamp termminals (detachable), or compact slotted,
screw terminals (detachable) G3J-S405BL INSTRUCTION MANUAL.
Certified for CSA and EN (TÜV).
The G3PF-2@@B-@@@ Series is UL certified.
Related products
OMRON
Soft-start/stop Solid State Contactors
G3J-T405BL DC12-24
OMRON Soft-start/stop Solid State Contactors G3J-T405BL DC12-24
Numer of elements: 3. Insulation method: Ph
OMRON
Soft-start Solid State Contactors
G3J-S205BL DC12-24
OMRON Soft-start Solid State Contactors G3J-S205BL DC12-24
Numer of elements: 3. Insulation method: Ph
OMRON
Soft-start Solid State Contactors
G3J-S211BL DC12-24
OMRON Soft-start Solid State Contactors G3J-S211BL DC12-24
Numer of elements: 3. Insulation method: Ph
OMRON
Soft-start Solid State Contactors
G3J-S405BL DC12-24
OMRON Soft-start Solid State Contactors G3J-S405BL DC12-24
Numer of elements: 3. Insulation method: Ph