Size: 48 x 96mm.
Category: power AC100 ~ 240V with.
Shell color: black.
Control output 1: output unit mode.
Control output 2: output unit mode.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
The detection function of the broken wire and SSR fault of heater: detection function of single phase or three phase heater E5ZN-2QPH03TC-FLK Manual.
Event entry point: 2.
Transfer output: -
E5ZN-2QPH03TC-FLK
Remote SP:4 to 20mA input.
Communication: RS-485.
General thermostat new high performance (high resolution, high speed, high precision input) type products.
Support simple operation, preventive maintenance.
A new type of liquid crystal, which can communicate with the front through the infrared port, is adopted,
Visual angle, contrast can be improved E5ZN-2QPH03TC-FLK Manual.
High resolution 5 bit display / can display 0.01 degrees C.
High speed sampling period 60ms.
All models complete a variety of (to the thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Also supports remote SP.
Add PV/SV status display function, convenient to check the state of the thermostat (automatic / manual, RUN/STOP, alarm),
Interactive display PV/SV E5ZN-2QPH03TC-FLK Manual.
By supporting software (Ver.4.0 CX-Thermo) to carry out a simple function (AND/OR logic and delay),
Be able to execute flexible contact output.
Increase the control output ON/OFF number counting function, can predict the temperature controller internal relay fault OMRON E5ZN-2QPH03TC-FLK INSTRUCTION Manual.
Position ratio type. Size: 1/16 DIN 48 × 48 × 78 (W × H × D).
Power supply voltage: 100 to 240 VAC OMRON E5ZN-2QPH03TC-FLK INSTRUCTION Manual.
Input type: Thermocouple or Resistance thermometer.
Alarm output: 2.
option units Mounting: No.
Control output: Voltage output(for driving SSR).
Previous mode: E5CZ-Q2.
This Best-selling General-purpose,
48×48-mm Temperature Controller,
Is Now Even Better.
Controllers now available with analog inputs OMRON E5ZN-2QPH03TC-FLK INSTRUCTION Manual.
Faster sampling at 250 ms.
Transfer output provided for easy output to recorders.
Models availaable with a loop break alarm (LBA) and,
heater short alarm (HS alarm) E5ZN-2QPH03TC-FLK .
Easy setting with 11-segment displays.
Setting protection indicator informs operator when,
protection is enabled.
Manual output provided.
New protoocol called Modbus is installed in the models,
with communications E5ZN-2QPH03TC-FLK Manual.
USB-Serial conversion cable is available.
Note: Refer to Precautions on page 33.