Product model: A616AD
Name: AD conversion module
Brand: MITSUBISHI
Sort: PDF datasheet
File language: English
File size: 2.54MB
Input type: DC input, positive common end.
Input points: 16 points.
Enter the response time: 0.2ms the following.
Rated input voltage / current: DC24V/5mA.
Output form: transistor output, leakage type.
Output points: 16 points.
OFF leakage current: 0.25mA.
Output protection function.
Rated load voltage / current: DC24V/0 MITSUBISHI AD conversion module PDF datasheet. 1A.
External connection: 1 line /1 line type A616AD
Fast connector type.
Simple wiring through quick connector.
Can be installed along the 6 direction.
MITSUBISHI PLC program simulation debugging
The basic idea of program simulation debugging is,
In order to facilitate the form of simulation to generate the actual state of the scene,
Create the necessary environmental conditions for the operation of the program MITSUBISHI AD conversion module PDF datasheet.
Depending on the way the field signals are generated,
The simulation debugging has two forms of hardware simulation and software simulation. Input points: 32 points.
Voltage: AC100 ~ 120V.
Current: 12mA.
Response time: 25ms.
32 points / a common end.
38 point terminal station.
CE certification.
System program memory for storing system program,
Including management procedures, monitoring procedures, as well as the user program to do the compiler to compile the process of interpretation MITSUBISHI AD conversion module PDF datasheet.
Read only memory. Manufacturers use, content can not be changed, power does not disappear A616AD PDF datasheet.
PLC selection with the development of PLC technology, more and more types of PLC products,
Function is becoming more and more perfect, and its application is more and more extensive A616AD PDF datasheet.
Different series of different models of PLC has different performance, applicable occasions also have different emphasis,
Price also has a greater difference. Therefore PLC selection,
Under the premise of meeting the control requirements,
Should consider the best performance to price ratio, a reasonable choice of PLC A616AD PDF datasheet.
Each scanning process. Focus on the input signal sampling. Focus on the output signal to refresh.
Input refresh process. When the input port is closed,
Program in the implementation phase, the input end of a new state, the new state can not be read.
Only when the program is scanned, the new state is read.
A scan cycle is divided into the input sample, the program execution, the output refresh.
The contents of the component image register are chaanged with the change of the execution of the program A616AD PDF catalog.
The length of the scan cycle is determined by the three.
CPU the speed of executing instructions.
Time of instruction.
Instruction count.
Due to thhe adoption of centralized sampling MITSUBISHI AD conversion module PDF datasheet.
Centralized output mode.
There exist input / output hysteresis phenomena, i.e., the input / output response delay.
Related products
MITSUBISHI
Temperature input module
A616TD
MITSUBISHI Temperature input module A616TD
16 channels. A616td and a68rd3/4 thermocouple
MITSUBISHI
Power module
A61PN
MITSUBISHI Power module A61PN
Input voltage range: AC100 120V/AC200 240
MITSUBISHI
Analog output module
A616DAI
MITSUBISHI Analog output module A616DAI
16 channels. Input: DC0 20mA. Output resol
MITSUBISHI
AD conversion module
A616AD
MITSUBISHI AD conversion module A616AD
16 channels. Input: DC-10 10V, DC-20 20mA