LK Automation Limited
Home >> Download >> MITSUBISHI >> Catalog Download >> AJ65FBTA4-16DE PDF catalog MITSUBISHI AJ65FBTA4-16DE datasheet PDF datasheet

AJ65FBTA4-16DE PDF catalog MITSUBISHI AJ65FBTA4-16DE datasheet PDF datasheet

Product model: AJ65FBTA4-16DE
Name: Waterproof connector type DC input module
Brand: MITSUBISHI
Sort: PDF datasheet
File language: English
File size: 8.82MB
Type of input: DC leakage.
Input points: 32 points.
Input voltage: 12/24.
Input current: 3/7mA.
Connection mode: terminal row.
Common common point: 32.
Functional block diagram language is a kind of PLC programming language, which is similar to digital logic circuit.
The function module is used to represent the function of the module,
Different function modules have different functions MITSUBISHI AJ65FBTA4-16DE PDF datasheet AJ65FBTA4-16DE
Functional module figure programming language features: functional block diagram programming language is characterized by a functional module for the unit,
Analysis and understanding of the control scheme is simple and easy: function module is to use graphical form of expression,
Intuitive, for a digital logic circuit based on the design of the staff is very easy to master the programming;
Control system with complex scale and complex control logic,
Because the function module diagram can clearly express the function relation, the programming debugging time is greatly reduced MITSUBISHI AJ65FBTA4-16DE PDF datasheet. Can connect the transmitter units 2 units using radius of about 50 meters (outdoor 200 meters).
According to the control requirements of the system, using the appropriate design method to design MITSUBISHI PLC program MITSUBISHI AJ65FBTA4-16DE PDF datasheet.
Procedures to meet the requirements of system control as the main line,
Write one by one to achieve the control function or the sub task of the program,
Gradually improve the functions specified by the system.
MITSUBISHI PLC initialization procedure. After MITSUBISHI PLC on power, the general need to do some of the initial operation,
In order to start making necessary preparations, to avoid the wrong operation of the system.
The main contents of the initialization program are: to some data area, counter and so on,
Data needed to restore some of the data area,
Set or reset some relays,
For some initial state display, etc.. Peripheral equipment A/QnA series CPU unit connection cable.RS-232:1 channel, RS-422:1 channel.
BASIC program mode (A3MCPU corresponding): BASIC console interface to use.
Sequential program mode (program controller CPU correspondence): non sequential computer connection interface and use.
How to choose MITSUBISHI PLC.
MITSUBISHI PLC options include the choice of MITSUBISHI PLC models, capacity, I/O module, power, etc..
MITSUBISHI PLC distribution I/O points and design MITSUBISHI PLC peripheral hardware circuit
Draw the I/O point of the PLC and the input / output device connection diagram or the corresponding table,
This part also can be carried out in second steps.
Design PLC peripherall hardware circuit AJ65FBTA4-16DE PDF catalog.
Draw the electrical wiring diagram of the other parts of the system,
Including the main circuit and the control circuit does not enter the PLC, etc..
The electrical schematic diagram of the system compoosed of I/O PLC connection diagram and PLC peripheral electrical circuit diagram AJ65FBTA4-16DE PDF catalog.
So far the system''s hardware electrical circuit has been determined.