Size: 48 x 48mm.
Body: terminal type.
Type: control output 1 point type (power AC/DC24V).
Shell color: black.
Control output: current output.
Control mode: standard or heating cooling.
Auxiliary output points: 2 points.
The failure detection function of the heater with the broken line and SSR: -.
Event input points: - E3Z-L61-ECON 0.3M PDF datasheet .
Transfer output: output (using control output)
E3Z-L61-ECON 0.3M
Communication: RS-485.
General thermostat new high performance (high resolution, high speed, high precision input) type products.
Support simple operation, preventive maintenance, using a new type of liquid crystal, visual angle, contrast to enhance.
High resolution 5 bit display / can display 0.01 degrees C (to achieve a small size of 48 x 48mm) E3Z-L61-ECON 0.3M PDF datasheet .
High speed sampling period 60ms.
All models (thermocouple /Pt/ analog input switching), 1 machines to support a variety of sensors.
Add PV/SV state display function, to see the state of the thermostat.
(automatic / manual, RUN/STOP, alarm), interactive display PV/SV.
By supporting software (CX-ThermoVer.4.0) to carry out a simple function (AND/OR logic and delay),
Be able to execute flexible contact output
Increase the control output ON/OFF number counting function, can predict the temperature controller internal relay faultTerminal type: Exposed-lead Models E3Z-L61-ECON 0.3M PDF datasheet .
Protective tubing diameter D (mm): 1.6 dia.
Protective tubing length L: 35cm OMRON E3Z-L61-ECON 0.3M PDF catalog.
Lead wire type: Heat resistive .
Lead wire length M : 2m.
A Wide Variety of High-precision.
Temperature Sensors OMRON E3Z-L61-ECON 0.3M PDF catalog.
Previous models with M3 screw connections have been joined,
by new models with ferrules to help reduce wiring work.
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according,
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal OMRON E3Z-L61-ECON 0.3M PDF catalog. Control output 1: Relay output.
Control output 2: Relay output.
Auxiliary output: Two.
Communications: RS-485.
Heater burnout: One.
Event inputs: Two.
Power supply voltage: 24 VAC/VDC.
Large White PV Display That’s Easier to Read.
Easy to Use, from Model Selection to Setup and Operation.
A CComplete Range of I/O Capacities,
Functions, and Performance E3Z-L61-ECON 0.3M datasheet.
Handles More Applications.
The white PV display with a height of 15.2 mm improves visibility.
High-speed sampling at 50 ms.
Short body with depth of only 60 mm E3Z-L61-ECON 0.3M PDF datasheet .
Easy connections to a PLC with programless communications.
Use component communications to link Temperature,
Controllers to each other.