CV500-VP CPU Bus Unit Personal Computer Unit Main Mem CV500-VP217-E.
8-MB memory; w/o floating-point processor.Size: 60mm.
Type: 4 lines.
Lighting voltage: DC24V.
Color: green.
Large tactile buttons and uniform lighting to create a general space.
Backlight brings a uniform, elegant and pleasant lighting OMRON CP1E-N40SDT-D PDF datasheet.
Large tactile buttons are easier to touch.
Drive rod mechanism to keep the direction of the parallel button, even if the pressure on the side of the
CP1E-N40SDT-D
Damping mechanism to ensure high impact resistance.
A slim body with a thickness of 14.6 mm. Model: CPM2A-20CDT1-D. Power supply: DC power supply.
Output type: Transistor sourcing.
Inputs points: 12 points.
Outputs points: 8 points.Model: CPM2C-16EDM OMRON CP1E-N40SDT-D PDF datasheet. Units with inputs only.
1 MIL connector.
Inputs: 16 inputs.
Outputs: ---.
Input type: 24 VDC.
Output type: --.Model : CVM1D-PA208.
8A.
Attach two things in the same format in each base Please you.Description : Connects peripheral port to RS232C computer port (Use with CS1W-CN114).Unit type: CJ1 Special I/O Units.
Product name: Analog Input Unit.
I/O points: 4 inputs;
Signal range selection: 1 to 5 V, 0 to 5 V,
0 to 10 V, -10 to 10 V, 4 to 20mA;
1/4,000(Settable to 1/8,000)*2 OMRON CP1E-N40SDT-D PDF datasheet.
Conversion period: 1 ms/point,
(250 μs/point can also be set.)*2.
Accuracy at ambient temperature of 25°C:
Voltage: ±0.2% of F. S. Current: ±0.4% of F.S.
External connection: Removable terminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.42A; 24V, --.
Standards: UC1, N, L, CE.
Consistent Microsecond Throughput:
Models with Direct Conversion Join the Lineup.
Analog Input Units for converting analog input,
signals into binary data.
Analog Output Units for converting binary ,
data into analog output signals. Unit type: CS1 Special I/O Units.
Product name: Isolated-type,
Analog Output Unit.
Output points : 4 inputs.
Signal range selection:
Set separately for each input.
Signal range: 4 to 20 mA, 1 to 5 V.
Conversion speed (resolution):
100ms/4 inputs.
Externa connection: Removable erminal block.
No. of unit numbers allocated: 1.
Current consumption: 5V, 0.15A; 26V, 0.16A.
Standards: UC1, CE.
Provides the functionality of isolators,
power supplies, signal converters,
and other devices.
The Analog Input Unit converts analog,
input signals such as 1 to 5 V or 4 to 20mA,
into digital values, and takes the values,
scaled in industrial units, and transfers,
it to the CPU Unit as the process value.
Because of this, no ladder program is required,
at the CPU Unit for scaling.
The Analog Output Unit converts analog output set,
values from the CPU Unit to analog output signals,
such as 4 to 20 mA or 1 to 5 V, and outputs them.
The built-in functions, such as measurement value,
alarms, rate-of-change calculations, and square roots,
have enabled major savings in cost and space comppared,
with previous systems CP1E-N40SDT-D PDF catalog.
High-resolution Models and 8-point Input Models are,
also available.
By combining the Units, logging/monitoring.
systems can be constructed,
or the Units can be used together with LCBs/LCCUs,
to construct complete process control systems CP1E-N40SDT-D PDF catalog.
Parameters can be easily displayed and set in an,
easy-to-understand form without special tools.